Research on secondary voltage distortion of three-phase three-element combined transformer basedon Yyn0 wiring mode

At the combined instrument transformer operation site, it was found that a three-phase three-element combined instrument transformer under Yyn0 connection had a surge in secondary side voltage harmonic content after years of operation. Aiming at the abnormal phenomenon of harmonic voltage on the secondary side of combined transformer, this paper analyzes the generation mechanism of harmonic voltage when the neutral point of the primary side is suspended, determines the key factors affecting the phenomenon, and verifies it through the simulation model of three-phase three-element combined transformer built by Maxwell. Tests simulating field conditions were carried out on a three-phase four-wire combined transformer test platform. The data error between the secondary side voltage test value and the simulation value did not exceed 5%, verifying the effectiveness of the simulation model.

Authors

Institutions

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/ic2ecs64405.2024.10928556
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on secondary voltage distortion of three-phase three-element combined transformer basedon Yyn0 wiring mode

Jiefu Zhang, Gang Liu, Yifei Zhou, Jie Geng et al.
Advanced DC-DC Converters
article

Research on secondary voltage distortion of three-phase three-element combined transformer basedon Yyn0 wiring mode

Jiefu Zhang, Gang Liu, Yifei Zhou, Jie Geng, Yong Liu
article en

Abstract

At the combined instrument transformer operation site, it was found that a three-phase three-element combined instrument transformer under Yyn0 connection had a surge in secondary side voltage harmonic content after years of operation. Aiming at the abnormal phenomenon of harmonic voltage on the secondary side of combined transformer, this paper analyzes the generation mechanism of harmonic voltage when the neutral point of the primary side is suspended, determines the key factors affecting the phenomenon, and verifies it through the simulation model of three-phase three-element combined transformer built by Maxwell. Tests simulating field conditions were carried out on a three-phase four-wire combined transformer test platform. The data error between the secondary side voltage test value and the simulation value did not exceed 5%, verifying the effectiveness of the simulation model.

State Grid Corporation of China (China) (CN), Shanghai Electric (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 73%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on secondary voltage distortion of three-phase three-element combined transformer basedon Yyn0 wiring mode — Jiefu Zhang, Gang Liu, et al. · (2024) | TGRS Research Map | TGRS