Converter Transformer Fault Diagnosis Based on Domain Adaptive Semi-Supervision, Lightweight and Model Compression

Aiming at the problem that deep learning cannot directly read one-dimensional dissolved gas data in oil, a wavelet transform data dimension conversion method based on the generalized Gaussian function is proposed to convert one-dimensional fault samples into two-dimensional The characteristic image is used to satisfy the data Diagnostic format of the converter transformer fault diagnosis method and at the same time, domain adaptive semi-supervised loss is introduced to optimize the model parameters. In view of the characteristics of existing deep learning models with many parameters and complex structures, a method based on lightweight neural networks and model compression is proposed to integrate and reduce deep learning models through convolutional layers and batch-normalization (BN) layers. The method of model compression by adjusting the bit-width of the parameters not only can effectively compress the deep learning model with almost no loss of model accuracy, but also improves the fault identification efficiency. In addition, the method can be successfully deployed on the edge computing platform, which realizes the effective utilization of resources and real-time response.

Authors

Institutions

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/eiecc64539.2024.10929099
Primary Topic
Smart Grid and Power Systems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Converter Transformer Fault Diagnosis Based on Domain Adaptive Semi-Supervision, Lightweight and Model Compression

Zhengqin Zhou, Weihao Sun, Jing Zhang, Min Zhang et al.
Smart Grid and Power Systems
article

Converter Transformer Fault Diagnosis Based on Domain Adaptive Semi-Supervision, Lightweight and Model Compression

Zhengqin Zhou, Weihao Sun, Jing Zhang, Min Zhang, Yang Xu, Yongpeng Xu
article en

Abstract

Aiming at the problem that deep learning cannot directly read one-dimensional dissolved gas data in oil, a wavelet transform data dimension conversion method based on the generalized Gaussian function is proposed to convert one-dimensional fault samples into two-dimensional The characteristic image is used to satisfy the data Diagnostic format of the converter transformer fault diagnosis method and at the same time, domain adaptive semi-supervised loss is introduced to optimize the model parameters. In view of the characteristics of existing deep learning models with many parameters and complex structures, a method based on lightweight neural networks and model compression is proposed to integrate and reduce deep learning models through convolutional layers and batch-normalization (BN) layers. The method of model compression by adjusting the bit-width of the parameters not only can effectively compress the deep learning model with almost no loss of model accuracy, but also improves the fault identification efficiency. In addition, the method can be successfully deployed on the edge computing platform, which realizes the effective utilization of resources and real-time response.

State Grid Corporation of China (China) (CN), Shanghai Jiao Tong University (CN)
State Grid Corporation of China
Climate action
Openalex Percentile: Top 73%
Smart Grid and Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.