Background : Compared with other placements, thigh-worn accelerometers offer the advantage to accurately capture postures. However, the lack of standardized sensor placement on the thigh raises concerns about the comparability and harmonization of data across studies. This study aimed to investigate the impact of sensor placement on thigh-worn accelerometer measurements. Methods : Thirty-six participants wore two sensors simultaneously at center- and upper-thigh position on the same thigh during daily activities for several days. Metrics of vector magnitude (Euclidian Norm Minus One), postures, and activities generated by GGIR and ActiPASS were analyzed with Bland–Altman plots and linear regressions. Results : The findings revealed a significant dependence of vector magnitude on sensor placement: 1 cm higher distance between the center- and upper-thigh position was correlated with almost 1 mg higher difference in Euclidian Norm Minus One between the two positions ( b = 0.94; 95% confidence interval [0.26, 1.62]). For time spent sedentary ( b = 0.03; 95% confidence interval [−2.48, 2.55]) and intense physical activities ( b = 0.22; 95% confidence interval [−0.10, 0.54]), the sensor position had no significant effect on the results. High concordance was also observed for other activities, such as walking, running, and sleeping. Conclusions : The analyses suggest that, despite variations in sensor placement, thigh-worn accelerometry data can be compared and harmonized for most postures and activities when analyzed by ActiPASS. The robust metrics by ActiPASS to accelerometer placements is likely because it utilizes multiple features in the acceleration signal (e.g., inclination, rotation) to classify activities and postures, rather than relying on a single feature (vector magnitude).

Authors

Institutions

Publication Details

Journal
Journal for the Measurement of Physical Behaviour
Published
2025-01-01
DOI
https://doi.org/10.1123/jmpb.2024-0043
Citations
2
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
9.52

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing Physical Activity Metrics From Different Placements of Thigh-Worn Accelerometers

Pasan Hettiarachchi, Peter Johansson, Fabio Franzese, Matthew N. Ahmadi et al.
2 citations
Journal for the Measurement of Physical Behaviour
Balance, Gait, and Falls Prevention
9.52
article

Comparing Physical Activity Metrics From Different Placements of Thigh-Worn Accelerometers

Pasan Hettiarachchi, Peter Johansson, Fabio Franzese, Matthew N. Ahmadi, Andreas Holtermann
article en
2 citations

Abstract

Background : Compared with other placements, thigh-worn accelerometers offer the advantage to accurately capture postures. However, the lack of standardized sensor placement on the thigh raises concerns about the comparability and harmonization of data across studies. This study aimed to investigate the impact of sensor placement on thigh-worn accelerometer measurements. Methods : Thirty-six participants wore two sensors simultaneously at center- and upper-thigh position on the same thigh during daily activities for several days. Metrics of vector magnitude (Euclidian Norm Minus One), postures, and activities generated by GGIR and ActiPASS were analyzed with Bland–Altman plots and linear regressions. Results : The findings revealed a significant dependence of vector magnitude on sensor placement: 1 cm higher distance between the center- and upper-thigh position was correlated with almost 1 mg higher difference in Euclidian Norm Minus One between the two positions ( b = 0.94; 95% confidence interval [0.26, 1.62]). For time spent sedentary ( b = 0.03; 95% confidence interval [−2.48, 2.55]) and intense physical activities ( b = 0.22; 95% confidence interval [−0.10, 0.54]), the sensor position had no significant effect on the results. High concordance was also observed for other activities, such as walking, running, and sleeping. Conclusions : The analyses suggest that, despite variations in sensor placement, thigh-worn accelerometry data can be compared and harmonized for most postures and activities when analyzed by ActiPASS. The robust metrics by ActiPASS to accelerometer placements is likely because it utilizes multiple features in the acceleration signal (e.g., inclination, rotation) to classify activities and postures, rather than relying on a single feature (vector magnitude).

Journal for the Measurement of Physical BehaviourVol. 8(1)
Uppsala University (SE), The University of Sydney (AU), Uppsala University Hospital (SE), National Research Centre for the Working Environment (DK)
Bundesministerium für Bildung und Forschung, Vetenskapsrådet, Forskningsrådet om Hälsa, Arbetsliv och Välfärd
Openalex Percentile: Top 4%
Balance, Gait, and Falls Prevention
9.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.