Solar Powered EV Charging Station with Improved Adaptive LMS Control for V2G and G2V Operation

A sustainable and effective charging infrastructure is essential to using electric vehicles (EVs). The challenges of developing a sustainable and efficient EV charging infrastructure are addressed in this study by offering a novel solution: a solar PV-based charging system combined with a Zero Attracting Improved Proportionate Normalised Least Mean Square (IZA-PNLMS) adaptive control algorithm IZA-PNLMS performs better than the existing method in minimizing harmonic distortion, preserving voltage stability, and enabling optimal power extraction from solar panels, efficient EV charging, and smooth grid integration due to its faster convergence, lower error, and DC offset rejection. This article discusses the proposed technology, implementation, and performance evaluation in depth to achieve grid compliance, improved power quality, and sustained and effective EV charging. By examining simulation results under several transient modes, the proper V2G and G2V methods are confirmed.

Authors

Institutions

Publication Details

Published
2025-02-21
DOI
https://doi.org/10.1109/setcom64758.2025.10932338
Primary Topic
Photovoltaic System Optimization Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Solar Powered EV Charging Station with Improved Adaptive LMS Control for V2G and G2V Operation

Ramakanta Panigrahi, Kaibalya Prasad Panda
Photovoltaic System Optimization Techniques
article

Solar Powered EV Charging Station with Improved Adaptive LMS Control for V2G and G2V Operation

Ramakanta Panigrahi, Kaibalya Prasad Panda
article en

Abstract

A sustainable and effective charging infrastructure is essential to using electric vehicles (EVs). The challenges of developing a sustainable and efficient EV charging infrastructure are addressed in this study by offering a novel solution: a solar PV-based charging system combined with a Zero Attracting Improved Proportionate Normalised Least Mean Square (IZA-PNLMS) adaptive control algorithm IZA-PNLMS performs better than the existing method in minimizing harmonic distortion, preserving voltage stability, and enabling optimal power extraction from solar panels, efficient EV charging, and smooth grid integration due to its faster convergence, lower error, and DC offset rejection. This article discusses the proposed technology, implementation, and performance evaluation in depth to achieve grid compliance, improved power quality, and sustained and effective EV charging. By examining simulation results under several transient modes, the proper V2G and G2V methods are confirmed.

Pandit Deendayal Energy University (IN)
Affordable and clean energy
Openalex Percentile: Top 96%
Photovoltaic System Optimization Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.