Study on Lightning Performance of UHV Project in High Altitude Area

In this study, the characteristics of lightning parameters along a typical high-altitude UHV (Ultra High Voltage) transmission project are statistically analyzed, and the distribution law of lightning activity and a series of key lightning parameters along the line are obtained. According to the lightning activity characteristics and engineering design conditions of the line corridor in typical high-altitude areas, the lightning performance simulation analysis of 1000 kV transmission lines and substations along the line in high altitude areas is carried out based on the electromagnetic transient simulation program. The lightning trip-out rate level along the high-altitude areas and the whole line of the project and the lightning invasion wave overvoltage level of 1000 kV substations in high-altitude areas are obtained. Finally, the arrangement method of arrester in 1000 kV substation is put forward, and the lightning protection design scheme of the whole project and the insulation coordination scheme of the equipment in the station are checked. The research results provide technical support for engineering design and safe operation.

Authors

Institutions

Publication Details

Published
2024-12-13
DOI
https://doi.org/10.1109/icpe64565.2024.10929348
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on Lightning Performance of UHV Project in High Altitude Area

Lei Wan, Xiangyu Yang, Mian Fan, Weimin Yang
High-Voltage Power Transmission Systems
article

Study on Lightning Performance of UHV Project in High Altitude Area

Lei Wan, Xiangyu Yang, Mian Fan, Weimin Yang
article en

Abstract

In this study, the characteristics of lightning parameters along a typical high-altitude UHV (Ultra High Voltage) transmission project are statistically analyzed, and the distribution law of lightning activity and a series of key lightning parameters along the line are obtained. According to the lightning activity characteristics and engineering design conditions of the line corridor in typical high-altitude areas, the lightning performance simulation analysis of 1000 kV transmission lines and substations along the line in high altitude areas is carried out based on the electromagnetic transient simulation program. The lightning trip-out rate level along the high-altitude areas and the whole line of the project and the lightning invasion wave overvoltage level of 1000 kV substations in high-altitude areas are obtained. Finally, the arrangement method of arrester in 1000 kV substation is put forward, and the lightning protection design scheme of the whole project and the insulation coordination scheme of the equipment in the station are checked. The research results provide technical support for engineering design and safe operation.

China Electric Power Research Institute
Climate action
Openalex Percentile: Top 73%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.