Validation of GEMS operational v2.0 total column NO2 and HCHO during the GMAP/SIJAQ campaign

The Geostationary Environmental Monitoring Spectrometer (GEMS), the first geostationary air quality instrument, onboard the GEO-KOMPSAT-2B (GK2B) satellite, produces hourly observations over Asia with 3.5 km × 8 km spatial resolution. To evaluate the GEMS L2 products, the National Institute of Environmental Research (NIER) organized the GEMS Map of Air Pollutants 2021 (GMAP2021) and the Satellite Integrated Joint monitoring of Air Quality 2022 (SIJAQ2022) campaigns during October 2021 to November 2021 and from June 2022 to July 2022, respectively. While GMAP2021 mainly targeted the SMA (Seoul Metropolitan Area), the SIJAQ2022 campaign extended to the southeastern area of South Korea. In this study, a comparison between Pandora and Multi-AXis Differential Optical Absorption Spectroscopy (MAX-DOAS) products and an evaluation of the GEMS operational v2.0 total column NO<sub>2</sub> and HCHO products are conducted. A comparative analysis between the Pandora (P189) and the IUP Bremen MAX-DOAS instrument at the Incheon NIER-ESC site was performed to analyze discrepancies between the retrieval processors (Pandora: PGN official processor, MAX-DOAS: MMF in FRM<sub>4</sub>DOAS framework). Aligning the viewing directions of both Pandora and MAX-DOAS leads to a significant increase in the slope and correlation coefficient from 0.87 to 0.96 and from 0.86 to 0.96, respectively, in the case of NO<sub>2</sub> tropospheric columns. Similarly, for HCHO tropospheric columns, slope and correlation coefficient change from 0.94 to 1.09 and from 0.81 to 0.90 when matching the viewing geometries of both instruments. In contrast to tropospheric columns, total HCHO columns derived from Pandora (P189) direct-sun measurements show significantly larger values than the MAX-DOAS ones, with a mean relative difference (MRD) of 126 %. This bias can however be reduced to 33 % after suitable adjustment of the direct-sun retrieval settings. The GEMS v2.0 NO<sub>2</sub> total column product, evaluated over 6 official PGN sites in South Korea, shows good agreement with a correlation coefficient of 0.87 and similar seasonal and diurnal NO<sub>2</sub> variation. However, GEMS tends to report higher values than Pandora with a mean relative difference of +41 %. The magnitude of the GEMS overestimation is amplified in highly polluted conditions (i.e. during winter and at noontime). Compared to 6 MAX-DOAS stations and 6 Pandora stations, the GEMS HCHO product captures well the seasonal and diurnal variation of HCHO and shows good agreement both with MAX-DOAS and Pandora with slopes of 0.84 and 0.79, respectively, and correlation coefficients of 0.86 for both. Large columns, however, tend to be systematically underestimated.

Authors

Institutions

Publication Details

Journal
The Science of The Total Environment
Published
2025-03-25
DOI
https://doi.org/10.1016/j.scitotenv.2025.179190
Citations
9
Primary Topic
Atmospheric Ozone and Climate
Type
article
Field-Weighted Citation Impact
11.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of GEMS operational v2.0 total column NO2 and HCHO during the GMAP/SIJAQ campaign

Lim‐Seok Chang, Alexis Merlaud, Miriam Latsch, Martina M. Friedrich et al.
9 citations
The Science of The Total Environment
Atmospheric Ozone and Climate
11.71
article

Validation of GEMS operational v2.0 total column NO2 and HCHO during the GMAP/SIJAQ campaign

Lim‐Seok Chang, Alexis Merlaud, Miriam Latsch, Martina M. Friedrich, Chang‐Keun Song, Lisa K. Behrens, Kezia Lange, Rokjin J. Park, Bianca Lauster, Katharina Uhlmannsiek, Alexander Cede, Bianca Zilker, Martin Tiefengraber, Gaïa Pinardi, Kangho Bae, Thomas Wagner, Ermioni Dimitropoulou, Kwonho Jeon, Steffen Ziegler, Lucas Reischmann, Tim Bösch, Manuel Gebetsberger, Simona Ripperger-Lukošiūnaitė, Leon Kuhn, Andreas Richter, Michel Van Roozendaël, Hyunkee Hong, Hanlim Lee, Caroline Fayt
article en
9 citations

Abstract

The Geostationary Environmental Monitoring Spectrometer (GEMS), the first geostationary air quality instrument, onboard the GEO-KOMPSAT-2B (GK2B) satellite, produces hourly observations over Asia with 3.5 km × 8 km spatial resolution. To evaluate the GEMS L2 products, the National Institute of Environmental Research (NIER) organized the GEMS Map of Air Pollutants 2021 (GMAP2021) and the Satellite Integrated Joint monitoring of Air Quality 2022 (SIJAQ2022) campaigns during October 2021 to November 2021 and from June 2022 to July 2022, respectively. While GMAP2021 mainly targeted the SMA (Seoul Metropolitan Area), the SIJAQ2022 campaign extended to the southeastern area of South Korea. In this study, a comparison between Pandora and Multi-AXis Differential Optical Absorption Spectroscopy (MAX-DOAS) products and an evaluation of the GEMS operational v2.0 total column NO<sub>2</sub> and HCHO products are conducted. A comparative analysis between the Pandora (P189) and the IUP Bremen MAX-DOAS instrument at the Incheon NIER-ESC site was performed to analyze discrepancies between the retrieval processors (Pandora: PGN official processor, MAX-DOAS: MMF in FRM<sub>4</sub>DOAS framework). Aligning the viewing directions of both Pandora and MAX-DOAS leads to a significant increase in the slope and correlation coefficient from 0.87 to 0.96 and from 0.86 to 0.96, respectively, in the case of NO<sub>2</sub> tropospheric columns. Similarly, for HCHO tropospheric columns, slope and correlation coefficient change from 0.94 to 1.09 and from 0.81 to 0.90 when matching the viewing geometries of both instruments. In contrast to tropospheric columns, total HCHO columns derived from Pandora (P189) direct-sun measurements show significantly larger values than the MAX-DOAS ones, with a mean relative difference (MRD) of 126 %. This bias can however be reduced to 33 % after suitable adjustment of the direct-sun retrieval settings. The GEMS v2.0 NO<sub>2</sub> total column product, evaluated over 6 official PGN sites in South Korea, shows good agreement with a correlation coefficient of 0.87 and similar seasonal and diurnal NO<sub>2</sub> variation. However, GEMS tends to report higher values than Pandora with a mean relative difference of +41 %. The magnitude of the GEMS overestimation is amplified in highly polluted conditions (i.e. during winter and at noontime). Compared to 6 MAX-DOAS stations and 6 Pandora stations, the GEMS HCHO product captures well the seasonal and diurnal variation of HCHO and shows good agreement both with MAX-DOAS and Pandora with slopes of 0.84 and 0.79, respectively, and correlation coefficients of 0.86 for both. Large columns, however, tend to be systematically underestimated.

The Science of The Total EnvironmentVol. 974
Seoul National University (KR), University of Bremen (DE), Universität Innsbruck (AT), Royal Belgian Institute for Space Aeronomy (BE), Max Planck Institute for Chemistry (DE), Ulsan National Institute of Science and Technology (KR), National Institute of Environmental Research (KR), Pukyong National University (KR)
National Institute of Environmental Research, Korea Environmental Industry and Technology Institute
Climate action
Openalex Percentile: Top 1%
Atmospheric Ozone and Climate
11.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.