Application of second-order generalized integral PLL method when inverter connecting with grid under harmonic background

In case of large number of distributed generation (DG) connected to grid, harmonic pollution becomes more seriously. DGs and grid-connected inverters are expected to participate in grid operation and management responsibly. Especially when the grid meets serious harmonic pollution, inverter’s grid connecting manipulation requires very high-precision phase angle detection. In these years, as a novel phase locked loop (PLL) method, second-order generalized integral (SOGI) PLL attracts more and more attentions. For inverter grid connecting manipulation purpose, in this paper, relationship between SOGI controller parameters and its dynamic performance are analyzed firstly. Then via SOGI, positive sequence components are extracted accurately and rapidly from the seriously polluted grid voltage. Using this information, inverter grid connecting controller can be designed. Through Matlab/Simulink simulation tool, above proposed method is justified and simulation results show its effectiveness when inverter connecting with grid under serious harmonic pollution.

Authors

Institutions

Publication Details

Published
2024-12-13
DOI
https://doi.org/10.1109/icpe64565.2024.10929411
Primary Topic
Islanding Detection in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of second-order generalized integral PLL method when inverter connecting with grid under harmonic background

Yi Yang, Jie Chen, Shih-Chin Yang, Xin Chen et al.
Islanding Detection in Power Systems
article

Application of second-order generalized integral PLL method when inverter connecting with grid under harmonic background

Yi Yang, Jie Chen, Shih-Chin Yang, Xin Chen, Chun You, Yinjie Li
article en

Abstract

In case of large number of distributed generation (DG) connected to grid, harmonic pollution becomes more seriously. DGs and grid-connected inverters are expected to participate in grid operation and management responsibly. Especially when the grid meets serious harmonic pollution, inverter’s grid connecting manipulation requires very high-precision phase angle detection. In these years, as a novel phase locked loop (PLL) method, second-order generalized integral (SOGI) PLL attracts more and more attentions. For inverter grid connecting manipulation purpose, in this paper, relationship between SOGI controller parameters and its dynamic performance are analyzed firstly. Then via SOGI, positive sequence components are extracted accurately and rapidly from the seriously polluted grid voltage. Using this information, inverter grid connecting controller can be designed. Through Matlab/Simulink simulation tool, above proposed method is justified and simulation results show its effectiveness when inverter connecting with grid under serious harmonic pollution.

Chongqing University of Posts and Telecommunications (CN), State Grid Corporation of China (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 73%
Islanding Detection in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.