Pseudo–Contrast-enhanced US via Enhanced Generative Adversarial Networks for Evaluating Tumor Ablation Efficacy

Purpose To develop methods for creating pseudo-contrast-enhanced US (CEUS) by using an enhanced generative adversarial network and evaluate its ability to assess tumor ablation effectiveness. Materials and Methods This retrospective study included 1030 patients who underwent thyroid nodule ablation across seven centers from January 2020 to April 2023. A generative adversarial network-based model was developed for direct pseudo-CEUS generation from B-mode US and tested on thyroid, breast, and liver ablation datasets. The reliability of pseudo-CEUS was assessed using structural similarity index (SSIM), color histogram correlation, and mean absolute percentage error against real CEUS. Additionally, a subjective evaluation system was devised to validate its clinical value. The Wilcoxon signed rank test was employed to analyze differences in the data. Results The study included 1030 patients (mean age, 46.9 years ± 12.5 [SD]; 799 female and 231 male patients). For internal test set 1, the mean SSIM was 0.89 ± 0.05, while across external test sets 1-6, mean SSIM values ranged from 0.84 ± 0.08 to 0.88 ± 0.04. Subjective assessments affirmed the method's stability and near-realistic performance in evaluating ablation effectiveness. The thyroid ablation datasets had an average identification score of 0.49 (0.5 indicates indistinguishability), while the similarity average score for all datasets was 4.75 out of 5. Radiologists' assessments of residual blood supply were nearly consistent, with no differences in defining ablation zones between real and pseudo-CEUS. Conclusion The pseudo-CEUS method demonstrated high similarity to real CEUS in evaluating tumor ablation effectiveness. <b>Keywords:</b> Ablation Techniques, Ultrasound, Computer Applications-Virtual Imaging <i>Supplemental material is available for this article.</i> © RSNA, 2025.

Authors

Institutions

Publication Details

Journal
Radiology Artificial Intelligence
Published
2025-03-26
DOI
https://doi.org/10.1148/ryai.240370
Citations
3
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
4.08
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pseudo–Contrast-enhanced US via Enhanced Generative Adversarial Networks for Evaluating Tumor Ablation Efficacy

Zhikang Xu, Chenke Xu, Yahan Zhou, Hongmei Mi et al.
3 citations
Radiology Artificial Intelligence
Radiomics and Machine Learning in Medical Imaging
4.08
article

Pseudo–Contrast-enhanced US via Enhanced Generative Adversarial Networks for Evaluating Tumor Ablation Efficacy

Zhikang Xu, Chenke Xu, Yahan Zhou, Hongmei Mi, Binggang Xiao, Changsong Xu, Dong Xu, Vicky Y. Wang, Qi Liu, Sui Lin, Xiaofang Liu, Mei Song, Qingquan He, Jincao Yao, Jiang Tian, Chenjie Xu, Yuanfei Wu, Zubang Zhou, Jian Chen, Chen Chen, Yuqi Yan, Lingyan Zhou, Zhiwei Wu, J H Hao, Jiabin Yu, Qi Zhang, Li Yang
article en
3 citations

Abstract

Purpose To develop methods for creating pseudo-contrast-enhanced US (CEUS) by using an enhanced generative adversarial network and evaluate its ability to assess tumor ablation effectiveness. Materials and Methods This retrospective study included 1030 patients who underwent thyroid nodule ablation across seven centers from January 2020 to April 2023. A generative adversarial network-based model was developed for direct pseudo-CEUS generation from B-mode US and tested on thyroid, breast, and liver ablation datasets. The reliability of pseudo-CEUS was assessed using structural similarity index (SSIM), color histogram correlation, and mean absolute percentage error against real CEUS. Additionally, a subjective evaluation system was devised to validate its clinical value. The Wilcoxon signed rank test was employed to analyze differences in the data. Results The study included 1030 patients (mean age, 46.9 years ± 12.5 [SD]; 799 female and 231 male patients). For internal test set 1, the mean SSIM was 0.89 ± 0.05, while across external test sets 1-6, mean SSIM values ranged from 0.84 ± 0.08 to 0.88 ± 0.04. Subjective assessments affirmed the method's stability and near-realistic performance in evaluating ablation effectiveness. The thyroid ablation datasets had an average identification score of 0.49 (0.5 indicates indistinguishability), while the similarity average score for all datasets was 4.75 out of 5. Radiologists' assessments of residual blood supply were nearly consistent, with no differences in defining ablation zones between real and pseudo-CEUS. Conclusion The pseudo-CEUS method demonstrated high similarity to real CEUS in evaluating tumor ablation effectiveness. <b>Keywords:</b> Ablation Techniques, Ultrasound, Computer Applications-Virtual Imaging <i>Supplemental material is available for this article.</i> © RSNA, 2025.

Radiology Artificial IntelligenceVol. 7(3)
Tongji University (CN), Chinese Academy of Sciences (CN), Wenzhou Medical University (CN), Westlake University (CN), Huaian First People’s Hospital (CN), Zhejiang Cancer Hospital (CN), Gansu Provincial Hospital (CN), Taizhou Central Hospital (CN), The First People's Hospital of Wenling (CN), Affiliated Hangzhou First People's Hospital, Westlake University, School of Medicine (CN), Zhejiang Taizhou Hospital (CN), Tongji Hospital (CN), Shaoxing People's Hospital (CN), China Jiliang University (CN), Zhejiang University (CN), Nanjing Medical University (CN)
Good health and well-being
Openalex Percentile: Top 7%
Radiomics and Machine Learning in Medical Imaging
4.08
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.