Artificial intelligence model on images of functional dyspepsia

BACKGROUND Recently, it has been suggested that the duodenum may be the pathological locus of functional dyspepsia (FD). Additionally, an image-based artificial intelligence (AI) model was shown to discriminate colonoscopy images of irritable bowel syndrome from healthy subjects with an area under the curve (AUC) 0.95. AIM To evaluate an AI model to distinguish duodenal images of FD patients from healthy subjects. METHODS Duodenal images were collected from hospital records and labeled as "functional dyspepsia" or non-FD in electronic medical records. Helicobacter pylori (HP) infection status was obtained from the Japan Endoscopy Database. Google Cloud AutoML Vision was used to classify four groups: FD/HP current infection (n = 32), FD/HP uninfected (n = 35), non-FD/HP current infection (n = 39), and non-FD/HP uninfected (n = 33). Patients with organic diseases (e.g. , cancer, ulcer, postoperative abdomen, reflux) and narrow-band or dye-spread images were excluded. Sensitivity, specificity, and AUC were calculated. RESULTS In total, 484 images were randomly selected for FD/HP current infection, FD/HP uninfected, non-FD/current infection, and non-FD/HP uninfected. The overall AUC for the four groups was 0.47. The individual AUC values were as follows: FD/HP current infection (0.20), FD/HP uninfected (0.35), non-FD/current infection (0.46), and non-FD/HP uninfected (0.74). Next, using the same images, we constructed models to determine the presence or absence of FD in the HP-infected or uninfected patients. The model exhibited a sensitivity of 58.3%, specificity of 100%, positive predictive value of 100%, negative predictive value of 77.3%, and an AUC of 0.85 in HP uninfected patients. CONCLUSION We developed an image-based AI model to distinguish duodenal images of FD from healthy subjects, showing higher accuracy in HP-uninfected patients. These findings suggest AI-assisted endoscopic diagnosis of FD may be feasible.

Authors

Publication Details

Journal
Artificial Intelligence in Gastrointestinal Endoscopy
Published
2025-03-26
DOI
https://doi.org/10.37126/aige.v6.i1.105674
Citations
4
Primary Topic
Gastrointestinal motility and disorders
Type
article
Field-Weighted Citation Impact
7.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Artificial intelligence model on images of functional dyspepsia

Sohachi Nanjo, Ichiro Yasuda, Hiroshi Mihara, Iori Motoo et al.
4 citations
Artificial Intelligence in Gastrointestinal Endoscopy
Gastrointestinal motility and disorders
7.24
article

Artificial intelligence model on images of functional dyspepsia

Sohachi Nanjo, Ichiro Yasuda, Hiroshi Mihara, Iori Motoo, Haruka Fujinami, Takayuki Ando
article en
4 citations

Abstract

BACKGROUND Recently, it has been suggested that the duodenum may be the pathological locus of functional dyspepsia (FD). Additionally, an image-based artificial intelligence (AI) model was shown to discriminate colonoscopy images of irritable bowel syndrome from healthy subjects with an area under the curve (AUC) 0.95. AIM To evaluate an AI model to distinguish duodenal images of FD patients from healthy subjects. METHODS Duodenal images were collected from hospital records and labeled as "functional dyspepsia" or non-FD in electronic medical records. Helicobacter pylori (HP) infection status was obtained from the Japan Endoscopy Database. Google Cloud AutoML Vision was used to classify four groups: FD/HP current infection (n = 32), FD/HP uninfected (n = 35), non-FD/HP current infection (n = 39), and non-FD/HP uninfected (n = 33). Patients with organic diseases (e.g. , cancer, ulcer, postoperative abdomen, reflux) and narrow-band or dye-spread images were excluded. Sensitivity, specificity, and AUC were calculated. RESULTS In total, 484 images were randomly selected for FD/HP current infection, FD/HP uninfected, non-FD/current infection, and non-FD/HP uninfected. The overall AUC for the four groups was 0.47. The individual AUC values were as follows: FD/HP current infection (0.20), FD/HP uninfected (0.35), non-FD/current infection (0.46), and non-FD/HP uninfected (0.74). Next, using the same images, we constructed models to determine the presence or absence of FD in the HP-infected or uninfected patients. The model exhibited a sensitivity of 58.3%, specificity of 100%, positive predictive value of 100%, negative predictive value of 77.3%, and an AUC of 0.85 in HP uninfected patients. CONCLUSION We developed an image-based AI model to distinguish duodenal images of FD from healthy subjects, showing higher accuracy in HP-uninfected patients. These findings suggest AI-assisted endoscopic diagnosis of FD may be feasible.

Artificial Intelligence in Gastrointestinal EndoscopyVol. 6(1)
Openalex Percentile: Top 4%
Gastrointestinal motility and disorders
7.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.