A self-correction algorithm for positioning error in sequential point bending tests of a microbeam for Young’s modulus based on atomic force microscopy

The single-point bending method, based on atomic force microscopy (AFM), has been extensively validated for characterizing the structural mechanical properties of micro- and nanobeams. Nevertheless, the influence of AFM probe loading and positioning has yet to be subjected to comprehensive investigation. This paper proposes a novel bending-test method based on sequential loading points, in which a series of evenly distributed loads are applied along the length of the central axis on the upper surface of the cantilever. The preliminary measured values of Young’s modulus for an unknown alloy material were 193, 178, and 176 GPa, exhibiting a considerable degree of dispersion. An algorithm for self-correction of the positioning error was developed, and this resulted in a positioning error of 53 nm and a final converged Young’s modulus of 161 GPa.

Authors

Institutions

Publication Details

Journal
Nanotechnology and Precision Engineering
Published
2025-03-26
DOI
https://doi.org/10.1063/10.0036132
Primary Topic
Force Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A self-correction algorithm for positioning error in sequential point bending tests of a microbeam for Young’s modulus based on atomic force microscopy

Yuxin Liu, Linyan Xu
Nanotechnology and Precision Engineering
Force Microscopy Techniques and Applications
article

A self-correction algorithm for positioning error in sequential point bending tests of a microbeam for Young’s modulus based on atomic force microscopy

Yuxin Liu, Linyan Xu
article en

Abstract

The single-point bending method, based on atomic force microscopy (AFM), has been extensively validated for characterizing the structural mechanical properties of micro- and nanobeams. Nevertheless, the influence of AFM probe loading and positioning has yet to be subjected to comprehensive investigation. This paper proposes a novel bending-test method based on sequential loading points, in which a series of evenly distributed loads are applied along the length of the central axis on the upper surface of the cantilever. The preliminary measured values of Young’s modulus for an unknown alloy material were 193, 178, and 176 GPa, exhibiting a considerable degree of dispersion. An algorithm for self-correction of the positioning error was developed, and this resulted in a positioning error of 53 nm and a final converged Young’s modulus of 161 GPa.

Nanotechnology and Precision EngineeringVol. 8(3)
Tianjin University (CN)
Openalex Percentile: Top 95%
Force Microscopy Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A self-correction algorithm for positioning error in sequential point bending tests of a microbeam for Young’s modulus based on atomic force microscopy — Yuxin Liu, Linyan Xu · Nanotechnology and Precision Engineering (2025) | TGRS Research Map | TGRS