Sensing and detection performance of the novel, small-diameter OmniaSecure defibrillation lead: in-depth analysis from the LEADR trial

Chronic sensing performance of the OmniaSecure defibrillation lead demonstrated R-wave stability with a low rate of P-wave and T-wave oversensing, resolved predominantly by adjusting RV sensitivity. Further, VT/VF detection was successful and was not impacted when programmed to less sensitive settings. The OmniaSecure lead shows robust sensing and detection performance and programmability in ongoing follow-up.

Authors

Institutions

Publication Details

Journal
EP Europace
Published
2025-03-25
DOI
https://doi.org/10.1093/europace/euaf062
Citations
1
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sensing and detection performance of the novel, small-diameter OmniaSecure defibrillation lead: in-depth analysis from the LEADR trial

Paolo De Filippo, Robert D. Schaller, Pamela Kay Mason, Travis D. Richardson et al.
1 citations
EP Europace
Cardiac pacing and defibrillation studies
1.39
article

Sensing and detection performance of the novel, small-diameter OmniaSecure defibrillation lead: in-depth analysis from the LEADR trial

Paolo De Filippo, Robert D. Schaller, Pamela Kay Mason, Travis D. Richardson, Darius P. Sholevar, Prashanthan Sanders, George H. Crossley, Amy E. Thompson, Babak Bozorgnia, Rajeev K. Pathak, Maully J. Shah, Attila Mihálcz, Baerbel Maus, Ignasi Anguera, John S. Zakaib, François Philippon, Chad A. Bounds, Bernice Tsang, Meir Friedman, Bert Hansky, Katherin Arias
article en
1 citations

Abstract

Chronic sensing performance of the OmniaSecure defibrillation lead demonstrated R-wave stability with a low rate of P-wave and T-wave oversensing, resolved predominantly by adjusting RV sensitivity. Further, VT/VF detection was successful and was not impacted when programmed to less sensitive settings. The OmniaSecure lead shows robust sensing and detection performance and programmability in ongoing follow-up.

EP EuropaceVol. 27(4)
Australian National University (AU), Heart Rhythm Society (US), Hartford Hospital (US), Royal Adelaide Hospital (AU), Children's Hospital of Philadelphia (US), Hospital of the University of Pennsylvania (US), Bellvitge University Hospital (ES), Southlake Regional Health Center (CA), Bakken Museum (US), Medtronic (Ireland) (IE), Medtronic (United States) (US), Ospedale Papa Giovanni XXIII (IT), Universitätsklinikum Krems (AT), Klinikum Bielefeld (DE), Lehigh Valley Hospital (US), Minneapolis Heart Institute Foundation (US), University of Virginia Medical Center (US), Institut universitaire de cardiologie et de pneumologie de Québec (CA), Virtua Health (US), Université Laval (CA), University of Virginia (US), The University of Adelaide (AU), Vanderbilt University Medical Center (US)
Peace, Justice and strong institutions
Openalex Percentile: Top 21%
Cardiac pacing and defibrillation studies
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.