THE ROLE OF ULTRASONIC CARDIAC OUTPUT MONITOR IN EVALUATING STROKE VOLUME VARIATION TO DETERMINE FLUID RESPONSIVENESS IN PATIENTS WITH SHOCK

Background: Dynamic assessment of cardiac output (CO) with passive leg raise (PLR), stroke volume variation (SVV), and pulse pressure variation (PPV) offer effective and safe methods to predict fluid responsiveness in patients with shock. The primary aim of this study was to evaluate the reliability of CO and SVV readings with the ultrasonic cardiac output monitor (USCOM) 1A device compared to PPV measurements in determining fluid responsiveness of patients in shock. Materials and Method: Intubated and mechanically ventilated patients aged 18-95 with shock admitted to the medical intensive care unit from June 2019 to December 2020 were included in the study. Fluid responsiveness was assessed using PPV from arterial monitoring and CO/SVV using the USCOM 1A device. CO, PPV, and SVV data were recorded before and after PLR. Results: Out of 145 shock patients, 92 were included. Before the PLR maneuver, 67 patients had PPV values above 12% and were stated as fluid responsive. The SVV index measured by the USCOM device demonstrated good sensitivity (85%) and specificity (96%) in identifying fluid responsiveness. The agreement with PPV was substantial (Cronbach's alpha reliability: 0.718 [ P < 0.001]), and the index was internally consistent (kappa agreement: 0.707 [ P < 0.001]). The SVV index moderately correlated with PPV (R: 0.588 [ P = 0.001]). Regarding fluid responsiveness determined by PPV, the AUC value of SVV was 0.797 (0.701-0.894) (p: 0.001). Conclusion: SVV measured by the USCOM device is a reliable and practical tool for hemodynamic assessment in clinical practice, particularly when invasive methods are unsuitable.

Authors

Institutions

Publication Details

Journal
Shock
Published
2025-03-25
DOI
https://doi.org/10.1097/shk.0000000000002584
Citations
1
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

THE ROLE OF ULTRASONIC CARDIAC OUTPUT MONITOR IN EVALUATING STROKE VOLUME VARIATION TO DETERMINE FLUID RESPONSIVENESS IN PATIENTS WITH SHOCK

Volkan İnal, Pervin Hancı, Seval Orman, Serdar Efe
1 citations
Shock
Hemodynamic Monitoring and Therapy
2.01
article

THE ROLE OF ULTRASONIC CARDIAC OUTPUT MONITOR IN EVALUATING STROKE VOLUME VARIATION TO DETERMINE FLUID RESPONSIVENESS IN PATIENTS WITH SHOCK

Volkan İnal, Pervin Hancı, Seval Orman, Serdar Efe
article en
1 citations

Abstract

Background: Dynamic assessment of cardiac output (CO) with passive leg raise (PLR), stroke volume variation (SVV), and pulse pressure variation (PPV) offer effective and safe methods to predict fluid responsiveness in patients with shock. The primary aim of this study was to evaluate the reliability of CO and SVV readings with the ultrasonic cardiac output monitor (USCOM) 1A device compared to PPV measurements in determining fluid responsiveness of patients in shock. Materials and Method: Intubated and mechanically ventilated patients aged 18-95 with shock admitted to the medical intensive care unit from June 2019 to December 2020 were included in the study. Fluid responsiveness was assessed using PPV from arterial monitoring and CO/SVV using the USCOM 1A device. CO, PPV, and SVV data were recorded before and after PLR. Results: Out of 145 shock patients, 92 were included. Before the PLR maneuver, 67 patients had PPV values above 12% and were stated as fluid responsive. The SVV index measured by the USCOM device demonstrated good sensitivity (85%) and specificity (96%) in identifying fluid responsiveness. The agreement with PPV was substantial (Cronbach's alpha reliability: 0.718 [ P < 0.001]), and the index was internally consistent (kappa agreement: 0.707 [ P < 0.001]). The SVV index moderately correlated with PPV (R: 0.588 [ P = 0.001]). Regarding fluid responsiveness determined by PPV, the AUC value of SVV was 0.797 (0.701-0.894) (p: 0.001). Conclusion: SVV measured by the USCOM device is a reliable and practical tool for hemodynamic assessment in clinical practice, particularly when invasive methods are unsuitable.

ShockVol. 63(6)
Trakya University (TR), Ministry of Health (TR), Bursa Uludağ Üni̇versi̇tesi̇ (TR)
Good health and well-being
Openalex Percentile: Top 18%
Hemodynamic Monitoring and Therapy
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.