The influence of different implantation depths on the hemodynamics in the treatment of stenosis in the starting segment of vertebral arteries

Stent implantation depth significantly influences the hemodynamics of the vertebral and subclavian arteries in treating vertebral artery stenosis. This study utilized computational fluid dynamics (CFD) to analyze key hemodynamic parameters in a vertebral artery model with a stent implanted at different depths. Results showed that excessive stent extension into the subclavian artery alters local blood flow, increasing the risk of thrombosis and plaque formation. An optimal implantation depth of 1-2 mm minimizes these risks. These findings provide a theoretical basis for optimizing stent placement, improving the efficacy and safety of interventional treatments for vertebral artery stenosis.

Authors

Institutions

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2025-03-25
DOI
https://doi.org/10.1080/10255842.2025.2480269
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The influence of different implantation depths on the hemodynamics in the treatment of stenosis in the starting segment of vertebral arteries

Juan Su, Yonggang Wang, Qingsong Han, Yilin Zheng et al.
Computer Methods in Biomechanics & Biomedical Engineering
Coronary Interventions and Diagnostics
article

The influence of different implantation depths on the hemodynamics in the treatment of stenosis in the starting segment of vertebral arteries

Juan Su, Yonggang Wang, Qingsong Han, Yilin Zheng, Haiquan Feng
article en

Abstract

Stent implantation depth significantly influences the hemodynamics of the vertebral and subclavian arteries in treating vertebral artery stenosis. This study utilized computational fluid dynamics (CFD) to analyze key hemodynamic parameters in a vertebral artery model with a stent implanted at different depths. Results showed that excessive stent extension into the subclavian artery alters local blood flow, increasing the risk of thrombosis and plaque formation. An optimal implantation depth of 1-2 mm minimizes these risks. These findings provide a theoretical basis for optimizing stent placement, improving the efficacy and safety of interventional treatments for vertebral artery stenosis.

Computer Methods in Biomechanics & Biomedical EngineeringVol. 28(6)
University of Science and Technology of China (CN), Mongolian University of Science and Technology (MN), First Affiliated Hospital of Henan University of Science and Technology (CN)
National Natural Science Foundation of China, Natural Science Foundation of Inner Mongolia
Good health and well-being
Openalex Percentile: Top 90%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The influence of different implantation depths on the hemodynamics in the treatment of stenosis in the starting segment of vertebral arteries — Juan Su, Yonggang Wang, et al. · Computer Methods in Biomechanics & Biomedical Engineering (2025) | TGRS Research Map | TGRS