Effect Air Flow Rate on the Performance of Perforated Splash Fill Plate of Forced Draft Wet Cooling Tower

A wet cooling tower is an apparatus for transferring heat and mass that directly links hot water and air movement. Because the wet cooling tower provides a large surface area for heat and mass transfer, fill is essential to the tower. This study uses experiments to investigate the performance of a multi-level inclined perforated splash fill in a forced wet cooling tower (WTC). The packing has a 2.6%, 3%, and 3.6% perforation ratio and an inclination angle of 15 degrees, with five layers of galvanized plate fill. The hot water temperature is adjusted to 60 degrees Celsius. The airflow rate varies five times: 0.02033, 0.02631, 0.02995, 0.03770, and 0.04261 kg/s. The water flow rate is ± 0.0917 kg/s. The hot water at the inflow is 60 degrees Celsius. The findings of this study indicate that the cooling efficiency of cooling towers may be significantly improved by raising the mass airflow rate and adopting the suitable perforation ratio.

Authors

Institutions

Publication Details

Journal
Defect and diffusion forum/Diffusion and defect data, solid state data. Part A, Defect and diffusion forum
Published
2025-03-26
DOI
https://doi.org/10.4028/p-mm2d4b
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect Air Flow Rate on the Performance of Perforated Splash Fill Plate of Forced Draft Wet Cooling Tower

Zahrul Fuadi, Muhammad Ilham Maulana, Khairul Umurani, Ahmad Syuhada
1 links
Defect and diffusion forum/Diffusion and defect data, solid state data. Part A, Defect and diffusion forum
Adsorption and Cooling Systems
article

Effect Air Flow Rate on the Performance of Perforated Splash Fill Plate of Forced Draft Wet Cooling Tower

Zahrul Fuadi, Muhammad Ilham Maulana, Khairul Umurani, Ahmad Syuhada
article en

Abstract

A wet cooling tower is an apparatus for transferring heat and mass that directly links hot water and air movement. Because the wet cooling tower provides a large surface area for heat and mass transfer, fill is essential to the tower. This study uses experiments to investigate the performance of a multi-level inclined perforated splash fill in a forced wet cooling tower (WTC). The packing has a 2.6%, 3%, and 3.6% perforation ratio and an inclination angle of 15 degrees, with five layers of galvanized plate fill. The hot water temperature is adjusted to 60 degrees Celsius. The airflow rate varies five times: 0.02033, 0.02631, 0.02995, 0.03770, and 0.04261 kg/s. The water flow rate is ± 0.0917 kg/s. The hot water at the inflow is 60 degrees Celsius. The findings of this study indicate that the cooling efficiency of cooling towers may be significantly improved by raising the mass airflow rate and adopting the suitable perforation ratio.

Defect and diffusion forum/Diffusion and defect data, solid state data. Part A, Defect and diffusion forumVol. 441
Universitas Syiah Kuala (ID)
Openalex Percentile: Top 95%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect Air Flow Rate on the Performance of Perforated Splash Fill Plate of Forced Draft Wet Cooling Tower — Zahrul Fuadi, Muhammad Ilham Maulana, et al. · Defect and diffusion forum/Diffusion and defect data, solid state data. Part A, Defect and diffusion forum (2025) | TGRS Research Map | TGRS