Enhancing the Selectivity and Confinement of the Cu(II)‐Mediated Chan‐Lam Coupling for Use in Building Point‐of‐Care Diagnostics

Abstract The Cu(II)‐mediated Chan‐Lam coupling reaction offers several benefits for developing point‐of‐care detection devices on microelectrode arrays. However, achieving selectivity on borate ester‐based polymer surfaces has proven difficult due to background reactions. Fluorescence‐based studies were conducted using fluorescently labeled acetylene nucleophiles. Initial experiments revealed significant background fluorescence across the electrode array, indicating selectivity issues. Further investigation uncovered significant background reactions occurring even without copper. To address this, a strategy utilizing an arylbromide‐based polymer was developed, enhancing reaction selectivity by minimizing background non‐specific reactions. Exploration into the confinement mechanism revealed the role of acetylene in forming dimers, facilitating rapid consumption of Cu(II) reagents that escaped from the specific electrodes used. These findings offer a way to construct devices for the multiplex point‐of‐care detection of metabolites, improving performance and accuracy in diagnostic devices.

Authors

Institutions

Publication Details

Journal
ChemElectroChem
Published
2025-03-26
DOI
https://doi.org/10.1002/celc.202400642
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing the Selectivity and Confinement of the Cu(II)‐Mediated Chan‐Lam Coupling for Use in Building Point‐of‐Care Diagnostics

Kevin D. Moeller, Yu‐Chia Chang
4 links
ChemElectroChem
Biosensors and Analytical Detection
article

Enhancing the Selectivity and Confinement of the Cu(II)‐Mediated Chan‐Lam Coupling for Use in Building Point‐of‐Care Diagnostics

Kevin D. Moeller, Yu‐Chia Chang
article en

Abstract

Abstract The Cu(II)‐mediated Chan‐Lam coupling reaction offers several benefits for developing point‐of‐care detection devices on microelectrode arrays. However, achieving selectivity on borate ester‐based polymer surfaces has proven difficult due to background reactions. Fluorescence‐based studies were conducted using fluorescently labeled acetylene nucleophiles. Initial experiments revealed significant background fluorescence across the electrode array, indicating selectivity issues. Further investigation uncovered significant background reactions occurring even without copper. To address this, a strategy utilizing an arylbromide‐based polymer was developed, enhancing reaction selectivity by minimizing background non‐specific reactions. Exploration into the confinement mechanism revealed the role of acetylene in forming dimers, facilitating rapid consumption of Cu(II) reagents that escaped from the specific electrodes used. These findings offer a way to construct devices for the multiplex point‐of‐care detection of metabolites, improving performance and accuracy in diagnostic devices.

ChemElectroChemVol. 12(8)
Washington University in St. Louis (US)
Openalex Percentile: Top 95%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.