Broken Rotor Bar Fault Detection in Induction Machines Based on Rectified Three-Phase Stator Currents

Induction machines are widely used in industrial and household applications due to their efficiency in electromechanical energy conversion. However, broken rotor bars can significantly disrupt machine performance, typically manifesting as sideband harmonics near the fundamental frequency which can be utilized for fault detection. Nonetheless, frequency leakage can impede fault detection, concealing fault until substantial damage occurs. The proposed method, based on the rectified three-phase stator current (RTPSC), effectively reduces leakage frequency while maintaining the fault characteristic frequency (FCF) at its original amplitude. In addition, generate the fundamental harmonic at a frequency of 6 times. This approach aims to is to enhance diagnostic capabilities in the maintenance and monitoring of induction machines, improving operational efficiency and it also reduces the chance of catastrophic failures. The proposed methodology is tested on cases involving one, two, and three broken rotor bars, with the simulation results validated through experimental verification.

Authors

Institutions

Publication Details

Published
2024-12-25
DOI
https://doi.org/10.1109/icspis65223.2024.10931095
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Broken Rotor Bar Fault Detection in Induction Machines Based on Rectified Three-Phase Stator Currents

Vahid Abolghasemi, Mohammad Hoseintabar Marzebali, Saeed Hajnayeb, Seyyed Meysam Seyyedbarzegar et al.
Non-Destructive Testing Techniques
article

Broken Rotor Bar Fault Detection in Induction Machines Based on Rectified Three-Phase Stator Currents

Vahid Abolghasemi, Mohammad Hoseintabar Marzebali, Saeed Hajnayeb, Seyyed Meysam Seyyedbarzegar, Fatemeh Amerian
article en

Abstract

Induction machines are widely used in industrial and household applications due to their efficiency in electromechanical energy conversion. However, broken rotor bars can significantly disrupt machine performance, typically manifesting as sideband harmonics near the fundamental frequency which can be utilized for fault detection. Nonetheless, frequency leakage can impede fault detection, concealing fault until substantial damage occurs. The proposed method, based on the rectified three-phase stator current (RTPSC), effectively reduces leakage frequency while maintaining the fault characteristic frequency (FCF) at its original amplitude. In addition, generate the fundamental harmonic at a frequency of 6 times. This approach aims to is to enhance diagnostic capabilities in the maintenance and monitoring of induction machines, improving operational efficiency and it also reduces the chance of catastrophic failures. The proposed methodology is tested on cases involving one, two, and three broken rotor bars, with the simulation results validated through experimental verification.

University of Essex (GB), University of Shahrood (IR)
Affordable and clean energy
Openalex Percentile: Top 72%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Broken Rotor Bar Fault Detection in Induction Machines Based on Rectified Three-Phase Stator Currents — Vahid Abolghasemi, Mohammad Hoseintabar Marzebali, et al. · (2024) | TGRS Research Map | TGRS