Analysis of the Failure Causes in the Transmission Components of a 500kV Spring Circuit Breaker

This paper examines a severe SF6 leakage failure that occurred during the closing operation of a 500kV spring circuit breaker. Field inspection identified the failure location as the connection between the transmission main shaft and the gas chamber. Disassembly analysis revealed that the root cause was the damage to the bearing support seat inside the gas chamber, which caused the transmission main shaft to lose balance and generate eccentric force. This led to the damage of the external bearing and sealing sleeve, resulting in significant leakage. Microscopic morphology and composition analysis of the debris confirmed that the root cause was a casting defect in the bearing support seat of the transmission gas chamber, where severe alloy element segregation and numerous impurities led to structural looseness and insufficient strength. These defects made the bearing support seat unable to withstand the vibrations caused by the frequent operations of the circuit breaker, eventually leading to fracture.

Authors

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/ic2ecs64405.2024.10928632
Primary Topic
Power Line Inspection Robots
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the Failure Causes in the Transmission Components of a 500kV Spring Circuit Breaker

Mianjie Li, Jin Sun, Yibin Chen, Shaowu Li
Power Line Inspection Robots
article

Analysis of the Failure Causes in the Transmission Components of a 500kV Spring Circuit Breaker

Mianjie Li, Jin Sun, Yibin Chen, Shaowu Li
article en

Abstract

This paper examines a severe SF6 leakage failure that occurred during the closing operation of a 500kV spring circuit breaker. Field inspection identified the failure location as the connection between the transmission main shaft and the gas chamber. Disassembly analysis revealed that the root cause was the damage to the bearing support seat inside the gas chamber, which caused the transmission main shaft to lose balance and generate eccentric force. This led to the damage of the external bearing and sealing sleeve, resulting in significant leakage. Microscopic morphology and composition analysis of the debris confirmed that the root cause was a casting defect in the bearing support seat of the transmission gas chamber, where severe alloy element segregation and numerous impurities led to structural looseness and insufficient strength. These defects made the bearing support seat unable to withstand the vibrations caused by the frequent operations of the circuit breaker, eventually leading to fracture.

Affordable and clean energy
Openalex Percentile: Top 72%
Power Line Inspection Robots
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.