Leakage Current Suppressing Strategy for Multiple Transformerless Grid-Connected Inverters

There is a parasitic capacitance between the photovoltaic (PV) panel and the earth, which forms a common-mode loop with the single-phase transformerless PV grid-connected inverters. With the increasing PV permeability of distribution network, collected leakage current (i<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">cm</inf>_<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</inf>) will be generated in the distribution station area. Excessive i<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">cm</inf>_<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</inf> will not only lead to the increase of harmonics and losses, but also trigger leakage protection to cause power failure accidents. Firstly, the double Fourier expression of the i<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">cm</inf>_<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</inf> is derived, and on this basis, a uniform carrier phase shift strategy is proposed to suppress the i<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">cm</inf>_<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</inf>, and a dynamic tracking method of the minimum i<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">cm</inf>_<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</inf> based on disturbance-observation is proposed, and a simulation model is established to verify the effectiveness of the scheme, and the actual suppression effect can reduce the i<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">cm</inf>_<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</inf> by 90%.

Authors

Institutions

Publication Details

Published
2024-12-27
DOI
https://doi.org/10.1109/ic2ecs64405.2024.10928309
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Leakage Current Suppressing Strategy for Multiple Transformerless Grid-Connected Inverters

Ning Guo, Xiaoxing Lu, Xiaolong Xiao, Haiqing Huang et al.
Multilevel Inverters and Converters
article

Leakage Current Suppressing Strategy for Multiple Transformerless Grid-Connected Inverters

Ning Guo, Xiaoxing Lu, Xiaolong Xiao, Haiqing Huang, Fan Wu, Mingming Shi
article en

Abstract

There is a parasitic capacitance between the photovoltaic (PV) panel and the earth, which forms a common-mode loop with the single-phase transformerless PV grid-connected inverters. With the increasing PV permeability of distribution network, collected leakage current (i<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">cm</inf>_<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</inf>) will be generated in the distribution station area. Excessive i<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">cm</inf>_<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</inf> will not only lead to the increase of harmonics and losses, but also trigger leakage protection to cause power failure accidents. Firstly, the double Fourier expression of the i<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">cm</inf>_<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</inf> is derived, and on this basis, a uniform carrier phase shift strategy is proposed to suppress the i<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">cm</inf>_<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</inf>, and a dynamic tracking method of the minimum i<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">cm</inf>_<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</inf> based on disturbance-observation is proposed, and a simulation model is established to verify the effectiveness of the scheme, and the actual suppression effect can reduce the i<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">cm</inf>_<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">tot</inf> by 90%.

State Grid Corporation of China (China) (CN), Shanghai Electric (China) (CN)
State Grid Jiangsu Electric Power
Affordable and clean energy
Openalex Percentile: Top 73%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.