Comparison of three blood collection tubes for 16 biochemical analytes and stability assessment of selected analytes: VACUETTE <sup>®</sup> CAT serum Sep clot activator tube, VACUETTE <sup>®</sup> LH lithium heparin Sep tube, and VACUETTE <sup>®</sup

BackgroundAnalytical performance of VACUETTE® CAT Serum Fast Separator Tube (SFT; Greiner Bio-One, Austria), recently developed quick-clotting serum separator, was evaluated for correlation and stability, comparing with VACUETTE® CAT Serum Sep Clot Activator Tube (SST; Greiner Bio-One) and VACUETTE® LH Lithium Heparin Sep Tube (LiHep Tube; Greiner Bio-One).MethodFor 107 paired samples, 16 analytes (glucose, potassium, LDH, CRP, creatinine, AST, ALT, ALP, GGT, AFP, PSA, TSH, free T4, iPTH, CK-MB, and cardiac troponin I[cTnI]) were measured. Correlations were assessed using Passing-Bablok regression and paired t-tests. Differences were evaluated by comparing the mean percentage difference and estimated difference at medical decision limits (MDLs), to the acceptable desirable difference. For six analytes - glucose, potassium, LDH, AST, iPTH, and cTnI - known for different stabilities between sample types, stability was evaluated by comparing changes over time with desirable differences.ResultsAcross the evaluated range, SFT showed clinically comparable differences to SST, except for CK-MB which showed significant positive bias. Plasma exhibited unacceptable biases: negative for potassium and positive for LDH and CK-MB. Estimated differences at MDLs were acceptable in SFT except for potassium and CK-MB, while plasma showed unacceptable differences in potassium, LDH, creatinine, and CK-MB. LiHep Tube showed reduced stability than SST for all analytes except for iPTH, impairing retest reliability. SFT showed comparable stability except for LDH and iPTH, which showed slightly shortened stability.ConclusionsThe SFT demonstrated high correlation and comparable stability to SST, making it a suitable replacement for the LiHep Tube, as an alternative to SST for rapid testing.

Authors

Institutions

Publication Details

Journal
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Published
2025-03-25
DOI
https://doi.org/10.1177/00045632251329272
Citations
1
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
1.16
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of three blood collection tubes for 16 biochemical analytes and stability assessment of selected analytes: VACUETTE ® CAT serum Sep clot activator tube, VACUETTE ® LH lithium heparin Sep tube, and VACUETTE ®</sup

Yaerim Lee, Changhee Ha, Hye Sung Han, Yeo‐Min Yun et al.
1 citations
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Clinical Laboratory Practices and Quality Control
1.16
article

Comparison of three blood collection tubes for 16 biochemical analytes and stability assessment of selected analytes: VACUETTE ® CAT serum Sep clot activator tube, VACUETTE ® LH lithium heparin Sep tube, and VACUETTE ®</sup

Yaerim Lee, Changhee Ha, Hye Sung Han, Yeo‐Min Yun, Jong Do Seo, Hee‐Won Moon, Hanah Kim, Jang‐Hwan Choi, Mina Hur, Sung Hea Kim, Hyun Joong Kim, Bum Sung Kim, S.W. Shin
article en
1 citations

Abstract

BackgroundAnalytical performance of VACUETTE® CAT Serum Fast Separator Tube (SFT; Greiner Bio-One, Austria), recently developed quick-clotting serum separator, was evaluated for correlation and stability, comparing with VACUETTE® CAT Serum Sep Clot Activator Tube (SST; Greiner Bio-One) and VACUETTE® LH Lithium Heparin Sep Tube (LiHep Tube; Greiner Bio-One).MethodFor 107 paired samples, 16 analytes (glucose, potassium, LDH, CRP, creatinine, AST, ALT, ALP, GGT, AFP, PSA, TSH, free T4, iPTH, CK-MB, and cardiac troponin I[cTnI]) were measured. Correlations were assessed using Passing-Bablok regression and paired t-tests. Differences were evaluated by comparing the mean percentage difference and estimated difference at medical decision limits (MDLs), to the acceptable desirable difference. For six analytes - glucose, potassium, LDH, AST, iPTH, and cTnI - known for different stabilities between sample types, stability was evaluated by comparing changes over time with desirable differences.ResultsAcross the evaluated range, SFT showed clinically comparable differences to SST, except for CK-MB which showed significant positive bias. Plasma exhibited unacceptable biases: negative for potassium and positive for LDH and CK-MB. Estimated differences at MDLs were acceptable in SFT except for potassium and CK-MB, while plasma showed unacceptable differences in potassium, LDH, creatinine, and CK-MB. LiHep Tube showed reduced stability than SST for all analytes except for iPTH, impairing retest reliability. SFT showed comparable stability except for LDH and iPTH, which showed slightly shortened stability.ConclusionsThe SFT demonstrated high correlation and comparable stability to SST, making it a suitable replacement for the LiHep Tube, as an alternative to SST for rapid testing.

Annals of Clinical Biochemistry International Journal of Laboratory MedicineVol. 62(5)
Konkuk University (KR), Konkuk University Medical Center (KR)
Openalex Percentile: Top 24%
Clinical Laboratory Practices and Quality Control
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.