Design of a hybrid AI network circuit for epilepsy detection with 97.5% accuracy and low cost-latency

Epilepsy detection using artificial intelligence (AI) networks has gained significant attention. However, existing methods face challenges in accuracy, computational cost, and speed. CNN excel in feature extraction but suffer from high computational latency and power consumption, while SVM rely heavily on feature quality and expensive kernel computations, limiting real-time performance. Additionally, most CNN-SVM hybrid model lack hardware optimization, leading to inefficient implementations with poor accuracy-latency trade-offs. To address these issues, this paper designs a hybrid AI network-based method for epilepsy detection using electroencephalography (EEG) signals. First, a hybrid AI network was constructed using three convolutional layers, three pooling layers, and a Gaussian kernel SVM to achieve EEG epilepsy detection. Then, the design of the multiply-accumulate circuit was completed using a parallel-style row computation method, and a pipelined convolutional computation circuit was used to accelerate the convolutional computation and reduce the computational overhead and delay. Finally, a single-precision floating-point exponential and logarithmic computation circuit was designed to improve the speed and accuracy of data computation. The digital back-end of the hardware circuit was realized under the TSMC 65 nm process. Experimental results show that the circuit occupies an area of 3.20 mm<sup>2</sup>, consumes 4.28 mW of power, operates at a frequency of 10 MHz, and has an epilepsy detection latency of 0.008 s, which represents a 32% reduction in latency compared to those reported in the relevant literature. The database test results showed an epilepsy detection accuracy of 97.5%, a sensitivity of 97.6%, and a specificity of 97.2%.

Authors

Institutions

Publication Details

Journal
Frontiers in Physiology
Published
2025-03-26
DOI
https://doi.org/10.3389/fphys.2025.1514883
Citations
1
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of a hybrid AI network circuit for epilepsy detection with 97.5% accuracy and low cost-latency

Yi Gong, Junping Chen, Hanyu Shi, Zhikang Chen et al.
1 citations
Frontiers in Physiology
EEG and Brain-Computer Interfaces
1.43
article

Design of a hybrid AI network circuit for epilepsy detection with 97.5% accuracy and low cost-latency

Yi Gong, Junping Chen, Hanyu Shi, Zhikang Chen, Ke Yan, Lizhi Sheng, Xuanxu Chen, Yuejun Zhang
article en
1 citations

Abstract

Epilepsy detection using artificial intelligence (AI) networks has gained significant attention. However, existing methods face challenges in accuracy, computational cost, and speed. CNN excel in feature extraction but suffer from high computational latency and power consumption, while SVM rely heavily on feature quality and expensive kernel computations, limiting real-time performance. Additionally, most CNN-SVM hybrid model lack hardware optimization, leading to inefficient implementations with poor accuracy-latency trade-offs. To address these issues, this paper designs a hybrid AI network-based method for epilepsy detection using electroencephalography (EEG) signals. First, a hybrid AI network was constructed using three convolutional layers, three pooling layers, and a Gaussian kernel SVM to achieve EEG epilepsy detection. Then, the design of the multiply-accumulate circuit was completed using a parallel-style row computation method, and a pipelined convolutional computation circuit was used to accelerate the convolutional computation and reduce the computational overhead and delay. Finally, a single-precision floating-point exponential and logarithmic computation circuit was designed to improve the speed and accuracy of data computation. The digital back-end of the hardware circuit was realized under the TSMC 65 nm process. Experimental results show that the circuit occupies an area of 3.20 mm<sup>2</sup>, consumes 4.28 mW of power, operates at a frequency of 10 MHz, and has an epilepsy detection latency of 0.008 s, which represents a 32% reduction in latency compared to those reported in the relevant literature. The database test results showed an epilepsy detection accuracy of 97.5%, a sensitivity of 97.6%, and a specificity of 97.2%.

Frontiers in PhysiologyVol. 16
Ningbo University (CN), Ningbo No. 2 Hospital (CN), Ningbo University Affiliated Hospital (CN)
Openalex Percentile: Top 21%
EEG and Brain-Computer Interfaces
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.