Prolonged Trapping of Adeno-Associated Virus Capsids Reveals that Genome Packaging Affects Single-Ion Mass Spectrometry Measurements

Recombinant adeno-associated viruses (rAAVs) play an important role in gene therapy, yet the optimal preparation of these biotherapeutics remains challenging, with often incomplete incorporation of genome cargo, negatively affecting therapeutic use. Genome packaging has traditionally been difficult to investigate. Charge detection mass spectrometry (CDMS) has gained prominence, as it provides the ability to mass analyze and resolve empty and filled rAAVs, enabling the quantitative determination of empty-to-filled rAAV ratios. Such measurements require a high mass resolving power and depend on the unbiased detectability of the distinct rAAV particles. The mass resolving power in the Orbitrap mass analyzers scales with transient recording times. Therefore, we extended the capability of recording ions from 1 or 2 to 24 s. When we record these 24 s transients to analyze rAAVs, we not only observe a substantial improvement in accuracy and mass resolution but also find that this can lead to erroneous artifacts in the empty-to-filled ratios. Artifacts originate from the distinct behavior between orbiting ions from either empty or filled particles, mainly due to differences in desolvation and charge losses. Ions from empty rAAVs appear much more susceptible to charge losses, which negatively affect their tracing, artificially decreasing the empty-to-filled ratios. Further elucidating the causes of this undesirable ion behavior, we provide the means to minimize charge losses, thus regaining accurate AAV quantification at an increased charge precision and mass-resolving power. As the Orbitrap-based CDMS has become a method of choice to determine this important quality control attribute, our findings are important to avoid reporting incorrect empty-to-filled ratios.

Authors

Institutions

Publication Details

Journal
Journal of the American Chemical Society
Published
2025-03-24
DOI
https://doi.org/10.1021/jacs.4c13393
Citations
3
Primary Topic
Molecular Biology Techniques and Applications
Type
article
Field-Weighted Citation Impact
2.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prolonged Trapping of Adeno-Associated Virus Capsids Reveals that Genome Packaging Affects Single-Ion Mass Spectrometry Measurements

Alexander Makarov, Kyle L. Fort, Albert J. R. Heck, Victor C. Yin et al.
3 citations
Journal of the American Chemical Society
Molecular Biology Techniques and Applications
2.42
article

Prolonged Trapping of Adeno-Associated Virus Capsids Reveals that Genome Packaging Affects Single-Ion Mass Spectrometry Measurements

Alexander Makarov, Kyle L. Fort, Albert J. R. Heck, Victor C. Yin, Eduard H.T.M. Ebberink, Arjan Barendregt, Tobias P. Wörner, Evolène Deslignière
article en
3 citations

Abstract

Recombinant adeno-associated viruses (rAAVs) play an important role in gene therapy, yet the optimal preparation of these biotherapeutics remains challenging, with often incomplete incorporation of genome cargo, negatively affecting therapeutic use. Genome packaging has traditionally been difficult to investigate. Charge detection mass spectrometry (CDMS) has gained prominence, as it provides the ability to mass analyze and resolve empty and filled rAAVs, enabling the quantitative determination of empty-to-filled rAAV ratios. Such measurements require a high mass resolving power and depend on the unbiased detectability of the distinct rAAV particles. The mass resolving power in the Orbitrap mass analyzers scales with transient recording times. Therefore, we extended the capability of recording ions from 1 or 2 to 24 s. When we record these 24 s transients to analyze rAAVs, we not only observe a substantial improvement in accuracy and mass resolution but also find that this can lead to erroneous artifacts in the empty-to-filled ratios. Artifacts originate from the distinct behavior between orbiting ions from either empty or filled particles, mainly due to differences in desolvation and charge losses. Ions from empty rAAVs appear much more susceptible to charge losses, which negatively affect their tracing, artificially decreasing the empty-to-filled ratios. Further elucidating the causes of this undesirable ion behavior, we provide the means to minimize charge losses, thus regaining accurate AAV quantification at an increased charge precision and mass-resolving power. As the Orbitrap-based CDMS has become a method of choice to determine this important quality control attribute, our findings are important to avoid reporting incorrect empty-to-filled ratios.

Journal of the American Chemical SocietyVol. 147(13)
Utrecht University (NL), Thermo Fisher Scientific (Germany) (DE)
Nederlandse Organisatie voor Wetenschappelijk Onderzoek, Roche Diagnostics
Openalex Percentile: Top 12%
Molecular Biology Techniques and Applications
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.