A High‐Efficiency and Low‐Cost Luminescent Sensor for Rapid Cu<sup>2+</sup> Detection

In this work, a simple, low‐cost, rapid, and highly selective method for the detection of Cu 2+ is developed using luminescence core–shell structure Gd 2 O 3 :Eu 3+ @SiO 2 composites. The sample has been characterized by X‐ray diffraction, transmission electron microscopy, and photoluminescence. Systematic luminescence studies demonstrate that Gd 2 O 3 :Eu 3+ @SiO 2 exhibits a high quenching efficiency for Cu 2+ detection through the inner filter effect. Additionally, the fluorescence intensity of Gd 2 O 3 :Eu 3+ @SiO 2 decreases with the increasing concentration of Cu 2+ , and the low detection limit is 9.7 × 10 −5 M −1 . The sensing system is successfully applied to the detection of Cu 2+ in human urine samples, showing high recyclability. Furthermore, the fluorescence quenching mechanism of the Gd 2 O 3 :Eu 3+ @SiO 2 /Cu 2+ mixture is investigated in depth.

Authors

Institutions

Publication Details

Journal
Zeitschrift für anorganische und allgemeine Chemie
Published
2025-03-25
DOI
https://doi.org/10.1002/zaac.202500012
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A High‐Efficiency and Low‐Cost Luminescent Sensor for Rapid Cu2+ Detection

Lu Wang, Jian Su
2 links
Zeitschrift für anorganische und allgemeine Chemie
Molecular Sensors and Ion Detection
article

A High‐Efficiency and Low‐Cost Luminescent Sensor for Rapid Cu2+ Detection

Lu Wang, Jian Su
article en

Abstract

In this work, a simple, low‐cost, rapid, and highly selective method for the detection of Cu 2+ is developed using luminescence core–shell structure Gd 2 O 3 :Eu 3+ @SiO 2 composites. The sample has been characterized by X‐ray diffraction, transmission electron microscopy, and photoluminescence. Systematic luminescence studies demonstrate that Gd 2 O 3 :Eu 3+ @SiO 2 exhibits a high quenching efficiency for Cu 2+ detection through the inner filter effect. Additionally, the fluorescence intensity of Gd 2 O 3 :Eu 3+ @SiO 2 decreases with the increasing concentration of Cu 2+ , and the low detection limit is 9.7 × 10 −5 M −1 . The sensing system is successfully applied to the detection of Cu 2+ in human urine samples, showing high recyclability. Furthermore, the fluorescence quenching mechanism of the Gd 2 O 3 :Eu 3+ @SiO 2 /Cu 2+ mixture is investigated in depth.

Zeitschrift für anorganische und allgemeine ChemieVol. 651(8)
Hebei University of Engineering (CN)
Openalex Percentile: Top 94%
Molecular Sensors and Ion Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.