Prognostic implications of quantitative flow ratio and optical coherence tomography-guided neointimal characteristics in drug-coated balloon treatment for in-stent restenosis

The aim of this study was to investigate the relationship between quantitative flow ratio (QFR) after drug-coated balloon (DCB) treatment for in-stent restenosis (ISR) and between neointimal characteristics assessed by optical coherence tomography (OCT) and clinical outcomes. This single-center, retrospective, observational cohort study included ISR patients who underwent DCB angioplasty under OCT guidance. The primary outcome of the study was a target vessel failure (TVF), defined as a composite endpoint of cardiovascular death, target vessel myocardial infarction and target vessel revascularization. During a median follow-up of 756 days (IQR: 443.25, 1134.50), 204 ISR patients underwent OCT-guided DCB angioplasty, resulting in TVF development in 27 patients. At the post-procedural DCB angioplasty, the vessel-level QFR was significantly lower in the TVF group (0.89 [IQR: 0.87, 0.93] vs. 0.93 [IQR: 0.91, 0.96]; P < 0.001) than in the non-TVF group. Analysis of the qualitative characteristics of ISR lesions showed a significantly higher incidence of heterogeneous neointima in the TVF group compared with the non-TVF group (13 [48.15%] vs. 32 [18.08%]; P < 0.001). In the multivariable Cox regression analysis, low vessel-level QFR (HR per 0.1 increase: 0.11; 95% CI: 0.03-0.41; P < 0.001) and heterogeneous neointima were independently associated with TVF. The TVF rate of vessels with the 2 features was 10.69 times higher than that of all other vessels (95%CI [2.05-55.79]; log-rank P < 0.0001). Vessel-level QFR and heterogeneous neointima were independent factors associated with TVF in ISR patients after DCB angioplasty. Adding the QFR measure-ment to OCT findings may enable better discrimination of patients with subsequent TVF post-DCB angioplasty for ISR.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-03-25
DOI
https://doi.org/10.1038/s41598-024-83748-y
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prognostic implications of quantitative flow ratio and optical coherence tomography-guided neointimal characteristics in drug-coated balloon treatment for in-stent restenosis

Chancui Deng, Ning Gu, Bei Shi, Yongchao Zhao et al.
Scientific Reports
Coronary Interventions and Diagnostics
article

Prognostic implications of quantitative flow ratio and optical coherence tomography-guided neointimal characteristics in drug-coated balloon treatment for in-stent restenosis

Chancui Deng, Ning Gu, Bei Shi, Yongchao Zhao, Xiushi Li, Zhenglong Wang, Yizhen Deng, Pan Li, Shiwan Lu, Feng Wang
article en

Abstract

The aim of this study was to investigate the relationship between quantitative flow ratio (QFR) after drug-coated balloon (DCB) treatment for in-stent restenosis (ISR) and between neointimal characteristics assessed by optical coherence tomography (OCT) and clinical outcomes. This single-center, retrospective, observational cohort study included ISR patients who underwent DCB angioplasty under OCT guidance. The primary outcome of the study was a target vessel failure (TVF), defined as a composite endpoint of cardiovascular death, target vessel myocardial infarction and target vessel revascularization. During a median follow-up of 756 days (IQR: 443.25, 1134.50), 204 ISR patients underwent OCT-guided DCB angioplasty, resulting in TVF development in 27 patients. At the post-procedural DCB angioplasty, the vessel-level QFR was significantly lower in the TVF group (0.89 [IQR: 0.87, 0.93] vs. 0.93 [IQR: 0.91, 0.96]; P < 0.001) than in the non-TVF group. Analysis of the qualitative characteristics of ISR lesions showed a significantly higher incidence of heterogeneous neointima in the TVF group compared with the non-TVF group (13 [48.15%] vs. 32 [18.08%]; P < 0.001). In the multivariable Cox regression analysis, low vessel-level QFR (HR per 0.1 increase: 0.11; 95% CI: 0.03-0.41; P < 0.001) and heterogeneous neointima were independently associated with TVF. The TVF rate of vessels with the 2 features was 10.69 times higher than that of all other vessels (95%CI [2.05-55.79]; log-rank P < 0.0001). Vessel-level QFR and heterogeneous neointima were independent factors associated with TVF in ISR patients after DCB angioplasty. Adding the QFR measure-ment to OCT findings may enable better discrimination of patients with subsequent TVF post-DCB angioplasty for ISR.

Scientific ReportsVol. 15(1)
Zunyi Medical University (CN)
Openalex Percentile: Top 90%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.