Dynamic Performance of a Steel Road Sign with Multi-Material Electronic Signboard Under Mining-Induced Tremors from Different Mining Areas: Experimental and Numerical Research

This study investigates the dynamic performance of a road sign equipped with a multi-material electronic signboard subjected to mining-induced seismic tremors. The key innovative aspect lies in providing new insights into the dynamic performance of multi-material electronic signboards under high-energy mining tremors, enhancing their safety assessment in mining areas. Experimental modal analysis and finite element analysis were conducted, and the numerical model of the sign was calibrated by adjusting ground stiffness to align experimental and computational data. The fundamental natural frequencies and their corresponding mode shapes were identified as 2.75 Hz, 3.09 Hz, 8.46 Hz, and 13.50 Hz. Numerical results were validated using MAC methods, demonstrating strong agreement with experimental values and confirming the accuracy of the numerical predictions. Damping ratios of 3.79% and 3.71% for the first and second modes, respectively, were measured via hammer tests. To evaluate the sign's dynamic performance under high-energy mining-induced tremors, two events were applied as kinematic excitation of the structure. These tremors, recorded in different mining regions, exhibited significant variations in peak ground acceleration (PGA) and dominant frequency range. A key finding was that frequency matching between the dominant frequencies of the tremor and the natural frequencies of the sign had a greater impact on the sign's dynamic response than PGA. The Szombierki tremor, with dominant frequencies of 1.6-4.8 Hz, induced significantly higher stress and displacement compared to the Moskorzyn tremor (5-10 Hz) despite the latter having twice the PGA. These results highlight that a road sign structure can exhibit widely varying dynamic behaviors depending on the seismic characteristics of the mining zone. Therefore, a comprehensive assessment of mining-induced tremors in relation to the seismicity of specific areas is crucial for understanding their potential impact on such structures. The dynamic performance assessment also revealed that the electronic multi-material signboard did not undergo plastic deformation, confirming it as a safe material solution for use in mining areas.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-03-25
DOI
https://doi.org/10.3390/ma18071451
Primary Topic
Structural Health Monitoring Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Performance of a Steel Road Sign with Multi-Material Electronic Signboard Under Mining-Induced Tremors from Different Mining Areas: Experimental and Numerical Research

Paweł Boroń, Joanna Dulińska
Materials
Structural Health Monitoring Techniques
article

Dynamic Performance of a Steel Road Sign with Multi-Material Electronic Signboard Under Mining-Induced Tremors from Different Mining Areas: Experimental and Numerical Research

Paweł Boroń, Joanna Dulińska
article en

Abstract

This study investigates the dynamic performance of a road sign equipped with a multi-material electronic signboard subjected to mining-induced seismic tremors. The key innovative aspect lies in providing new insights into the dynamic performance of multi-material electronic signboards under high-energy mining tremors, enhancing their safety assessment in mining areas. Experimental modal analysis and finite element analysis were conducted, and the numerical model of the sign was calibrated by adjusting ground stiffness to align experimental and computational data. The fundamental natural frequencies and their corresponding mode shapes were identified as 2.75 Hz, 3.09 Hz, 8.46 Hz, and 13.50 Hz. Numerical results were validated using MAC methods, demonstrating strong agreement with experimental values and confirming the accuracy of the numerical predictions. Damping ratios of 3.79% and 3.71% for the first and second modes, respectively, were measured via hammer tests. To evaluate the sign's dynamic performance under high-energy mining-induced tremors, two events were applied as kinematic excitation of the structure. These tremors, recorded in different mining regions, exhibited significant variations in peak ground acceleration (PGA) and dominant frequency range. A key finding was that frequency matching between the dominant frequencies of the tremor and the natural frequencies of the sign had a greater impact on the sign's dynamic response than PGA. The Szombierki tremor, with dominant frequencies of 1.6-4.8 Hz, induced significantly higher stress and displacement compared to the Moskorzyn tremor (5-10 Hz) despite the latter having twice the PGA. These results highlight that a road sign structure can exhibit widely varying dynamic behaviors depending on the seismic characteristics of the mining zone. Therefore, a comprehensive assessment of mining-induced tremors in relation to the seismicity of specific areas is crucial for understanding their potential impact on such structures. The dynamic performance assessment also revealed that the electronic multi-material signboard did not undergo plastic deformation, confirming it as a safe material solution for use in mining areas.

MaterialsVol. 18(7)
Cracow University of Technology (PL)
Sustainable cities and communities
Openalex Percentile: Top 94%
Structural Health Monitoring Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.