Novel Design of a Transradial Socket to Allow Independent Pro-Supination Control in a Myoelectric Prosthesis

Background/Objectives: Individuals with transradial limb loss or absence often retain the ability to pro-supinate their forearm, but the traditional design of the prosthesis precludes this motion from being used for direct prosthesis control. Methods: A prosthetic arm was created for a single user that employed a novel split inner socket to allow pro-supination of the residuum to control a powered prosthetic wrist rotator. A total of 14 subjects (13 able-bodied subjects and one prosthesis user) performed the Refined Clothespin Relocation Test. The user performed the test with their own and a novel research prosthesis, which allowed independent hand and wrist function. Movements of limb segments were recorded using a motion capture system and an analysis of limb segment angles and compensatory motion was made. Results: The research prosthesis reduced compensation in the trunk and head and reduced pain in some joints, while the time to complete the test increased. Conclusions: This method has the potential to create additional intuitive control channels for transradial prostheses.

Authors

Institutions

Publication Details

Journal
Prosthesis
Published
2025-03-25
DOI
https://doi.org/10.3390/prosthesis7020033
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Design of a Transradial Socket to Allow Independent Pro-Supination Control in a Myoelectric Prosthesis

Peter Kyberd, Ali Hussaini
Prosthesis
Muscle activation and electromyography studies
article

Novel Design of a Transradial Socket to Allow Independent Pro-Supination Control in a Myoelectric Prosthesis

Peter Kyberd, Ali Hussaini
article en

Abstract

Background/Objectives: Individuals with transradial limb loss or absence often retain the ability to pro-supinate their forearm, but the traditional design of the prosthesis precludes this motion from being used for direct prosthesis control. Methods: A prosthetic arm was created for a single user that employed a novel split inner socket to allow pro-supination of the residuum to control a powered prosthetic wrist rotator. A total of 14 subjects (13 able-bodied subjects and one prosthesis user) performed the Refined Clothespin Relocation Test. The user performed the test with their own and a novel research prosthesis, which allowed independent hand and wrist function. Movements of limb segments were recorded using a motion capture system and an analysis of limb segment angles and compensatory motion was made. Results: The research prosthesis reduced compensation in the trunk and head and reduced pain in some joints, while the time to complete the test increased. Conclusions: This method has the potential to create additional intuitive control channels for transradial prostheses.

ProsthesisVol. 7(2)
University of New Brunswick (CA), Royal National Orthopaedic Hospital (GB), University College London (GB)
Openalex Percentile: Top 95%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.