The Aortic Magna Ease Bioprosthesis: Exploring Hemodynamic Performance Across Sexes and Prosthesis Sizes

Objective This study aims to assess the incidence of prosthesis–patient mismatch (PPM), the hemodynamic performance, as well as the clinical outcomes of the Carpentier-Edwards Magna Ease (CEME) bioprosthesis in the aortic position while addressing sex-based disparities and variations in valve size. Methods Between 2012 and 2022, 1062 patients underwent an AVR with a CEME bioprosthesis in two high-volume cardiac surgery centers. Predicted PPM was assessed using manufacturer and Lancellotti et al. chart values, alongside measured values. Echocardiographic measurements were evaluated over a 5-year period. Results Predicted PPM based on the manufacturer chart was noted in 2.1% of women and 0.28% of men ( P < .001). When employing definitions by Lancellotti et al., PPM was detected in 45% of females and 18% of males ( P < .001). Notable differences were observed in terms of severe measured PPM in favor of male patients (F: 30%, M: 17%, P < .01). Regarding prosthesis sizes, the comparison of PPM from the manufacturer's chart with Lancellotti et al. values revealed significant disparities: 2% versus 58% in the 19 to 21 mm group, 0.27% versus 13% in the 23 mm group, and 0% versus 1.1% in the ≥25 mm valve sizes ( P < .001). Measured severe PPM was encountered in 30% of patients with 19 to 21 mm prosthesis, 20% in the 23 mm group and 12% in the >25 mm prosthesis. Despite these differences, mortality rates remained comparable across sexes and valve sizes. Conclusion Female patients and those with 19 to 21 mm prostheses experience more severe PPM compared to men or individuals with larger valves. In this contemporary cohort, PPM does not impact short-term mortality.

Authors

Institutions

Publication Details

Journal
Journal of the Heart Valve Society
Published
2025-01-01
DOI
https://doi.org/10.1177/30494826241297119
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Aortic Magna Ease Bioprosthesis: Exploring Hemodynamic Performance Across Sexes and Prosthesis Sizes

Olivier Nguyen, Christine Pacheco, Dimitri Kalavrouziotis, Siamak Mohammadi et al.
Journal of the Heart Valve Society
Cardiac Valve Diseases and Treatments
article

The Aortic Magna Ease Bioprosthesis: Exploring Hemodynamic Performance Across Sexes and Prosthesis Sizes

Olivier Nguyen, Christine Pacheco, Dimitri Kalavrouziotis, Siamak Mohammadi, Eliza Calin, Jessica Forcillo, Roxanne St-Louis, Nicolas Noiseux, Louis‐Mathieu Stevens, A. Cartier
article en

Abstract

Objective This study aims to assess the incidence of prosthesis–patient mismatch (PPM), the hemodynamic performance, as well as the clinical outcomes of the Carpentier-Edwards Magna Ease (CEME) bioprosthesis in the aortic position while addressing sex-based disparities and variations in valve size. Methods Between 2012 and 2022, 1062 patients underwent an AVR with a CEME bioprosthesis in two high-volume cardiac surgery centers. Predicted PPM was assessed using manufacturer and Lancellotti et al. chart values, alongside measured values. Echocardiographic measurements were evaluated over a 5-year period. Results Predicted PPM based on the manufacturer chart was noted in 2.1% of women and 0.28% of men ( P < .001). When employing definitions by Lancellotti et al., PPM was detected in 45% of females and 18% of males ( P < .001). Notable differences were observed in terms of severe measured PPM in favor of male patients (F: 30%, M: 17%, P < .01). Regarding prosthesis sizes, the comparison of PPM from the manufacturer's chart with Lancellotti et al. values revealed significant disparities: 2% versus 58% in the 19 to 21 mm group, 0.27% versus 13% in the 23 mm group, and 0% versus 1.1% in the ≥25 mm valve sizes ( P < .001). Measured severe PPM was encountered in 30% of patients with 19 to 21 mm prosthesis, 20% in the 23 mm group and 12% in the >25 mm prosthesis. Despite these differences, mortality rates remained comparable across sexes and valve sizes. Conclusion Female patients and those with 19 to 21 mm prostheses experience more severe PPM compared to men or individuals with larger valves. In this contemporary cohort, PPM does not impact short-term mortality.

Journal of the Heart Valve SocietyVol. 2(1)
Institut universitaire de cardiologie et de pneumologie de Québec (CA), Centre Hospitalier de l’Université de Montréal (CA), Université Laval (CA), Université de Montréal (CA)
Edwards Lifesciences
Openalex Percentile: Top 91%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.