Sealing the Leak: Transcatheter Repair of Anterior Mitral Leaflet Perforation With Amplatzer Vascular Plug 4

We document the first reported use of the Amplatzer Vascular Plug 4 for anterior mitral leaflet perforation repair in a 56-year-old male who had undergone valve-in-valve transcatheter aortic valve replacement. Previously reported cases involving the use of other occluder devices for mitral leaflet perforation repair either required guide catheter or delivery sheath exchanges, arteriovenous wire loop for deployment, or use of mitral transcatheter edge-to-edge repair for leaflet stability. Our case highlights the efficacy of the bilobar-designed Amplatzer Vascular Plug 4 for precise occlusion in anterior mitral leaflet perforation through antegrade-only delivery and safety through the simplification of procedural steps.

Authors

Institutions

Publication Details

Journal
Journal of the Society for Cardiovascular Angiography & Interventions
Published
2025-03-26
DOI
https://doi.org/10.1016/j.jscai.2025.102634
Citations
2
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
2.78
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sealing the Leak: Transcatheter Repair of Anterior Mitral Leaflet Perforation With Amplatzer Vascular Plug 4

Laura Flannery, Steven J. Yakubov, Jordan Luli, Lindsay Castle et al.
2 citations
Journal of the Society for Cardiovascular Angiography & Interventions
Cardiac Valve Diseases and Treatments
2.78
article

Sealing the Leak: Transcatheter Repair of Anterior Mitral Leaflet Perforation With Amplatzer Vascular Plug 4

Laura Flannery, Steven J. Yakubov, Jordan Luli, Lindsay Castle, Zeryab Khan, Cody Carter, Carlos E. Sanchez, Kevin Stiver, Nathan Marzlin, Johnathan Hatanelas
article en
2 citations

Abstract

We document the first reported use of the Amplatzer Vascular Plug 4 for anterior mitral leaflet perforation repair in a 56-year-old male who had undergone valve-in-valve transcatheter aortic valve replacement. Previously reported cases involving the use of other occluder devices for mitral leaflet perforation repair either required guide catheter or delivery sheath exchanges, arteriovenous wire loop for deployment, or use of mitral transcatheter edge-to-edge repair for leaflet stability. Our case highlights the efficacy of the bilobar-designed Amplatzer Vascular Plug 4 for precise occlusion in anterior mitral leaflet perforation through antegrade-only delivery and safety through the simplification of procedural steps.

Journal of the Society for Cardiovascular Angiography & InterventionsVol. 4(5)
Riverside Methodist Hospital (US)
Openalex Percentile: Top 11%
Cardiac Valve Diseases and Treatments
2.78
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.