Empirically‐Derived Building‐Specific Learning Models for Predicting Occupant Vapor Intrusion Exposures

ABSTRACT Vapor intrusion (VI) is a chemical exposure pathway that refers to the migration of hazardous vapors from a subsurface vapor source, such as contaminated soil or groundwater, through the soil and into an overlying building or structure. Release and transport of these compounds through the VI pathway can result in health risks that are typically estimated by collecting and analyzing samples, representing the results as an average concentration over time, and then comparing these measurements to risk screening criteria established by regulatory agencies. These criteria determine which mitigation option, if any, is to be implemented, as well as the specified response timing. While spatial variability and temporal dynamics are well‐documented, the most common VI risk assessment approaches consist of samples collected via random timing driven by practitioner convenience and scheduling constraints. Previous studies have demonstrated that randomly timed sample results do not typically represent conservative conditions and are susceptible to underestimation and false negative results. More recent studies demonstrated that samples collected during upward vapor flux conditions driven by advective transport can result in improved risk assessments and a reduction in the potential for false negative conclusions. The current study builds upon these findings by generating empirical building‐specific correlations between barometric pressure patterns and exposure concentration measurements during upward flux conditions. These correlations are then used to predict past occupant exposure profiles by applying the building‐specific relationships to historical barometric pressure records. Three examples are described, and considerations for future VI investigations are presented. For each of these, a linear relationship between the barometric pressure drop rate and indoor concentration was observed. Subsequently, the most rapid drop in historic barometric pressure corresponded with a prediction of the highest indoor air concentration. This study represents the first time this type of building‐specific learning model has been developed and used to estimate occupant exposures. This novel exposure prediction approach has the potential to improve VI risk assessments and mitigation design and to expedite risk management decisions.

Authors

Institutions

Publication Details

Journal
Remediation Journal
Published
2025-01-01
DOI
https://doi.org/10.1002/rem.70016
Citations
1
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
3.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Empirically‐Derived Building‐Specific Learning Models for Predicting Occupant Vapor Intrusion Exposures

Ryan Solgi, Mark Kram
1 citations
Remediation Journal
Noise Effects and Management
3.12
article

Empirically‐Derived Building‐Specific Learning Models for Predicting Occupant Vapor Intrusion Exposures

Ryan Solgi, Mark Kram
article en
1 citations

Abstract

ABSTRACT Vapor intrusion (VI) is a chemical exposure pathway that refers to the migration of hazardous vapors from a subsurface vapor source, such as contaminated soil or groundwater, through the soil and into an overlying building or structure. Release and transport of these compounds through the VI pathway can result in health risks that are typically estimated by collecting and analyzing samples, representing the results as an average concentration over time, and then comparing these measurements to risk screening criteria established by regulatory agencies. These criteria determine which mitigation option, if any, is to be implemented, as well as the specified response timing. While spatial variability and temporal dynamics are well‐documented, the most common VI risk assessment approaches consist of samples collected via random timing driven by practitioner convenience and scheduling constraints. Previous studies have demonstrated that randomly timed sample results do not typically represent conservative conditions and are susceptible to underestimation and false negative results. More recent studies demonstrated that samples collected during upward vapor flux conditions driven by advective transport can result in improved risk assessments and a reduction in the potential for false negative conclusions. The current study builds upon these findings by generating empirical building‐specific correlations between barometric pressure patterns and exposure concentration measurements during upward flux conditions. These correlations are then used to predict past occupant exposure profiles by applying the building‐specific relationships to historical barometric pressure records. Three examples are described, and considerations for future VI investigations are presented. For each of these, a linear relationship between the barometric pressure drop rate and indoor concentration was observed. Subsequently, the most rapid drop in historic barometric pressure corresponded with a prediction of the highest indoor air concentration. This study represents the first time this type of building‐specific learning model has been developed and used to estimate occupant exposures. This novel exposure prediction approach has the potential to improve VI risk assessments and mitigation design and to expedite risk management decisions.

Remediation JournalVol. 35(2)
University of California, Santa Barbara (US)
Openalex Percentile: Top 12%
Noise Effects and Management
3.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.