Maximum likelihood bolometric tomography for DTT diagnostic design

On both the Joint European Torus (JET) and the ASDEX-Upgrade (AUG) tokamaks, an Expectation Maximization algorithm has been adapted to implement a Maximum Likelihood (ML) approach to derive tomograms from bolometers data. The main feature of such an approach is the ability to estimate the variance associated with the reconstructed tomograms and hence the uncertainties in the derived quantities. It has therefore been selected to support the design of the bolometric diagnostics for the Divertor Tokamak Test Facility (DTT). A reliable reconstruction of the emissivity profile is indeed relevant for the scientific exploitation of the device. As any tomographic inversion method is an ill-conditioned problem, two milestones should be achieved: ensuring the reconstruction of specific features and minimizing the risk of producing artefacts. The design strategy for the bolometric diagnostic on DTT involves testing various possible layouts to ensure that they meet the above requirements and are compatible with the engineering and machine constraints. This contribution focuses on showing how the conceptual bolometric layout can handle different phantoms mimicking typical emissivities observed on JET and AUG. A methodology has been developed to further optimize the layout within the constraints of the machine design. For the initial phase of DTT, a reduced layout is proposed, utilizing half of the conceptual lines of sight. The ability to reconstruct specific emissivity features while minimizing the risk of producing artefacts has been tested. The current ML implementation uses an anisotropic diffusion technique and is already significantly faster than the JET implementation for each reconstruction.

Authors

Institutions

Publication Details

Journal
Fusion Engineering and Design
Published
2025-03-25
DOI
https://doi.org/10.1016/j.fusengdes.2025.114947
Citations
5
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
6.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Maximum likelihood bolometric tomography for DTT diagnostic design

A. Belpane, M. Gelfusa, P. Gaudio, T. Craciunescu et al.
5 citations
Fusion Engineering and Design
Medical Imaging Techniques and Applications
6.80
article

Maximum likelihood bolometric tomography for DTT diagnostic design

A. Belpane, M. Gelfusa, P. Gaudio, T. Craciunescu, S. Palomba, G. Apruzzese, Vittorio D’Agostino, Luca Senni, E. Peluso, L. Boncagni
article en
5 citations

Abstract

On both the Joint European Torus (JET) and the ASDEX-Upgrade (AUG) tokamaks, an Expectation Maximization algorithm has been adapted to implement a Maximum Likelihood (ML) approach to derive tomograms from bolometers data. The main feature of such an approach is the ability to estimate the variance associated with the reconstructed tomograms and hence the uncertainties in the derived quantities. It has therefore been selected to support the design of the bolometric diagnostics for the Divertor Tokamak Test Facility (DTT). A reliable reconstruction of the emissivity profile is indeed relevant for the scientific exploitation of the device. As any tomographic inversion method is an ill-conditioned problem, two milestones should be achieved: ensuring the reconstruction of specific features and minimizing the risk of producing artefacts. The design strategy for the bolometric diagnostic on DTT involves testing various possible layouts to ensure that they meet the above requirements and are compatible with the engineering and machine constraints. This contribution focuses on showing how the conceptual bolometric layout can handle different phantoms mimicking typical emissivities observed on JET and AUG. A methodology has been developed to further optimize the layout within the constraints of the machine design. For the initial phase of DTT, a reduced layout is proposed, utilizing half of the conceptual lines of sight. The ability to reconstruct specific emissivity features while minimizing the risk of producing artefacts has been tested. The current ML implementation uses an anisotropic diffusion technique and is already significantly faster than the JET implementation for each reconstruction.

Fusion Engineering and DesignVol. 215
National Agency for New Technologies, Energy and Sustainable Economic Development (IT), University of Rome Tor Vergata (IT), National Institute for Laser Plasma and Radiation Physics (RO), Istituto Nazionale di Fisica Nucleare, Sezione di Padova (IT), Policlinico Tor Vergata (IT), Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Frascati (IT), IAC (United States) (US)
Openalex Percentile: Top 3%
Medical Imaging Techniques and Applications
6.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.