420 Harmonization of quality indicators in Clinical Microbiology Laboratories

Objectives/Goals: This study aims to harmonize quality indicators (QIs) across University of Toronto-affiliated microbiology labs to establish universal benchmarks that enhance performance, patient safety, and health outcomes. Harmonized QIs will enable effective comparisons and enhance the consistency of care. Methods/Study Population: The study employed the Delphi method, a structured and iterative process to build consensus. An expert panel of clinical microbiology trainees, medical microbiologists, trainees, and site leads from five University of Toronto-affiliated microbiology labs was assembled. Initial insights were gathered through surveys and a comprehensive scoping review of the literature. The study involved two rounds of feedback, a SurveyMonkey-based survey, with a defined consensus of 75% agreement among participants. Followed by an implementation survey conducted through REDCap to assess how these QIs were adopted in practice and identify barriers to implementation. Results/Anticipated Results: The study achieved consensus on nine high-impact quality indicators, including blood culture volume and contamination rates, cerebrospinal fluid transport time, and turnaround times for Gram stain results. Blood culture contamination and positivity rates garnered the highest agreement, at 100% and 91%, respectively. While some indicators were widely accepted and implemented, others faced resistance due to feasibility concerns. The study also identified significant variability in the level of adoption across the participating laboratories, pointing to operational challenges and the need for further efforts to address these barriers. Discussion/Significance of Impact: This study highlights the importance of QI harmonization in improving lab services and patient safety. It reveals challenges in standardizing practices but promotes uniformity in QIs, laying the groundwork for better inter-lab collaboration, consistent outcomes, and improvements in microbiology.

Authors

Institutions

Publication Details

Journal
Journal of Clinical and Translational Science
Published
2025-03-25
DOI
https://doi.org/10.1017/cts.2024.1028
Primary Topic
Bacterial Identification and Susceptibility Testing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

420 Harmonization of quality indicators in Clinical Microbiology Laboratories

Anand Shah, Ellen G. Avery, Susan M. Poutanen, Vivek Shukla et al.
Journal of Clinical and Translational Science
Bacterial Identification and Susceptibility Testing
article

420 Harmonization of quality indicators in Clinical Microbiology Laboratories

Anand Shah, Ellen G. Avery, Susan M. Poutanen, Vivek Shukla, Setareh Aghamohammadi, Laura Abbatangelo, Mawada Tarhuni, Janine Noorloos
article en

Abstract

Objectives/Goals: This study aims to harmonize quality indicators (QIs) across University of Toronto-affiliated microbiology labs to establish universal benchmarks that enhance performance, patient safety, and health outcomes. Harmonized QIs will enable effective comparisons and enhance the consistency of care. Methods/Study Population: The study employed the Delphi method, a structured and iterative process to build consensus. An expert panel of clinical microbiology trainees, medical microbiologists, trainees, and site leads from five University of Toronto-affiliated microbiology labs was assembled. Initial insights were gathered through surveys and a comprehensive scoping review of the literature. The study involved two rounds of feedback, a SurveyMonkey-based survey, with a defined consensus of 75% agreement among participants. Followed by an implementation survey conducted through REDCap to assess how these QIs were adopted in practice and identify barriers to implementation. Results/Anticipated Results: The study achieved consensus on nine high-impact quality indicators, including blood culture volume and contamination rates, cerebrospinal fluid transport time, and turnaround times for Gram stain results. Blood culture contamination and positivity rates garnered the highest agreement, at 100% and 91%, respectively. While some indicators were widely accepted and implemented, others faced resistance due to feasibility concerns. The study also identified significant variability in the level of adoption across the participating laboratories, pointing to operational challenges and the need for further efforts to address these barriers. Discussion/Significance of Impact: This study highlights the importance of QI harmonization in improving lab services and patient safety. It reveals challenges in standardizing practices but promotes uniformity in QIs, laying the groundwork for better inter-lab collaboration, consistent outcomes, and improvements in microbiology.

Journal of Clinical and Translational ScienceVol. 9(s1)
University of Toronto (CA)
Openalex Percentile: Top 92%
Bacterial Identification and Susceptibility Testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.