132 A novel microsampling measure to evaluate localized inflammation via amniotic fluid

Objectives/Goals: Intra-amniotic inflammation (IAI) is one of the leading causes of maternal/fetal morbidity globally, yet it is undiagnosed in 90–95% of cases. The purpose of this study was to assess precision and accuracy of a novel microsampling device for measuring cytokines in amniotic fluid (AF) to enable noninvasive evaluation of localized inflammation. Methods/Study Population: AF was obtained from discarded amniocentesis samples from 3 deidentified patients without known inflammation. Samples were spiked to 5 concentrations of interleukin-6 (IL-6) and tumor necrosis factor-a (TNF-a), then sampled using the Neoteryx Mitra volumetric microsampling device (20 µL). Dried/reconstituted samples were analyzed using the Luminex R&D Mag XL multiplex (IL-6, TNF-α) and compared to free-flowing AF. Inter-and intra-assay performances were evaluated across 5-runs in 3 standard cytokine concentrations. Recovery/linearity was assessed by a recovery curve and parameter estimates. Precision was assessed between-run and within-run using coefficients of variance (%CV). Accuracy was evaluated as agreement between microsampled and free-flowing AF using Bland–Altman plots. Results/Anticipated Results: TNF-α results were linear for all 3 patients across 5 concentrations. However, accuracy and recovery consistently failed (mean±SD percent recovery 176±21%). TNF-α results had acceptable precision with %CV within-run of 6.8–12.1% and across-runs of 14.0–15.9%. Microsampled TNF-α agreed with free-flowing sample: 16 of 18 (89%) were within 1SD of the mean difference (-24±36 pg/ml). IL-6 results were linear for 1/3 patients and had unacceptable accuracy and recovery for 13/15 samples (mean±SD percent recovery 764±469%). IL-6 results had acceptable precision (%CV within-run 6.2%, 7.5% and 11.2%; across-run .9–15.2%). Microsampled IL-6 agreed with free-flowing sample; 17 of 18 (94%) were within 1SD of the mean difference (-148±180pg/ml). Free-flowing vs. microsampling methods agreed best at low concentration. Discussion/Significance of Impact: This study provides preliminary support for noninvasive measurement of cytokines leveraging small amounts of leaking AF providing a promising alternative to amniocentesis and potential for assessing inflammation intrapartum. Clinical application requires development of reference ranges and association between cytokine levels and outcomes.

Authors

Institutions

Publication Details

Journal
Journal of Clinical and Translational Science
Published
2025-03-25
DOI
https://doi.org/10.1017/cts.2024.792
Primary Topic
Preterm Birth and Chorioamnionitis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

132 A novel microsampling measure to evaluate localized inflammation via amniotic fluid

Powell, Teri L. Hernandez, Katherine Kissler, Heidi Lennox
Journal of Clinical and Translational Science
Preterm Birth and Chorioamnionitis
article

132 A novel microsampling measure to evaluate localized inflammation via amniotic fluid

Powell, Teri L. Hernandez, Katherine Kissler, Heidi Lennox
article en

Abstract

Objectives/Goals: Intra-amniotic inflammation (IAI) is one of the leading causes of maternal/fetal morbidity globally, yet it is undiagnosed in 90–95% of cases. The purpose of this study was to assess precision and accuracy of a novel microsampling device for measuring cytokines in amniotic fluid (AF) to enable noninvasive evaluation of localized inflammation. Methods/Study Population: AF was obtained from discarded amniocentesis samples from 3 deidentified patients without known inflammation. Samples were spiked to 5 concentrations of interleukin-6 (IL-6) and tumor necrosis factor-a (TNF-a), then sampled using the Neoteryx Mitra volumetric microsampling device (20 µL). Dried/reconstituted samples were analyzed using the Luminex R&D Mag XL multiplex (IL-6, TNF-α) and compared to free-flowing AF. Inter-and intra-assay performances were evaluated across 5-runs in 3 standard cytokine concentrations. Recovery/linearity was assessed by a recovery curve and parameter estimates. Precision was assessed between-run and within-run using coefficients of variance (%CV). Accuracy was evaluated as agreement between microsampled and free-flowing AF using Bland–Altman plots. Results/Anticipated Results: TNF-α results were linear for all 3 patients across 5 concentrations. However, accuracy and recovery consistently failed (mean±SD percent recovery 176±21%). TNF-α results had acceptable precision with %CV within-run of 6.8–12.1% and across-runs of 14.0–15.9%. Microsampled TNF-α agreed with free-flowing sample: 16 of 18 (89%) were within 1SD of the mean difference (-24±36 pg/ml). IL-6 results were linear for 1/3 patients and had unacceptable accuracy and recovery for 13/15 samples (mean±SD percent recovery 764±469%). IL-6 results had acceptable precision (%CV within-run 6.2%, 7.5% and 11.2%; across-run .9–15.2%). Microsampled IL-6 agreed with free-flowing sample; 17 of 18 (94%) were within 1SD of the mean difference (-148±180pg/ml). Free-flowing vs. microsampling methods agreed best at low concentration. Discussion/Significance of Impact: This study provides preliminary support for noninvasive measurement of cytokines leveraging small amounts of leaking AF providing a promising alternative to amniocentesis and potential for assessing inflammation intrapartum. Clinical application requires development of reference ranges and association between cytokine levels and outcomes.

Journal of Clinical and Translational ScienceVol. 9(s1)
University of Colorado Anschutz Medical Campus (US)
Openalex Percentile: Top 92%
Preterm Birth and Chorioamnionitis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.