Identification of Polyamines in Human Milk, Formula Milk, and Other Dairy Products: a Special Method Based on Precolumn Derivatization, Double-Florisil Purification, and Gas Chromatography–Triple Quadrupole Mass Spectrometry

Polyamines in human milk are essential for the rapid growth and development of neonates and infants. However, the concentrations of polyamines in human milk have not been well characterized and the special methods for detecting polyamines in human milk, formula milk, or other dairy products remain largely unavailable to date. In this study, an accurate and sensitive method based on trifluoroacetic acid anhydride (TFAA) derivatization, double solid-phase extraction (SPE) purification, and gas chromatography-triple quadrupole mass spectrometry (GC-QqQ MS) was established for the evaluation of polyamines in human milk, formula milk, and other dairy products. High coefficients of determination for internal calibration curves were obtained (<i>R</i><sup>2</sup> > 0.99). Low limits of detection (5.0, 1.0, and 0.5 nmol/dL) and limits of quantification (10.0, 3.0, and 1.0 nmol/dL) for putrescine, spermidine, and spermine, respectively, were also achieved. The precision (expressed as relative standard deviation, RSD < 9.0%) and recovery rates (78.3-108.4%) were satisfactory. Spermidine and spermine in human milk were found significantly higher than those in formula milk and commercial cow's milk. The difference of polyamine content in human milk and infant formula should be paid attention to, particularly when infant formula is used as a complete replacement for human milk.

Authors

Institutions

Publication Details

Journal
Journal of Agricultural and Food Chemistry
Published
2025-03-25
DOI
https://doi.org/10.1021/acs.jafc.4c09966
Citations
1
Primary Topic
Polyamine Metabolism and Applications
Type
article
Field-Weighted Citation Impact
0.81

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identification of Polyamines in Human Milk, Formula Milk, and Other Dairy Products: a Special Method Based on Precolumn Derivatization, Double-Florisil Purification, and Gas Chromatography–Triple Quadrupole Mass Spectrometry

Jieshu Wu, Zhixu Wang, Lı Wang, Yuanyuan Li et al.
1 citations
Journal of Agricultural and Food Chemistry
Polyamine Metabolism and Applications
0.81
article

Identification of Polyamines in Human Milk, Formula Milk, and Other Dairy Products: a Special Method Based on Precolumn Derivatization, Double-Florisil Purification, and Gas Chromatography–Triple Quadrupole Mass Spectrometry

Jieshu Wu, Zhixu Wang, Lı Wang, Yuanyuan Li, Qin Zhang, Linjing Dong, Ding Ye, Yating Sun
article en
1 citations

Abstract

Polyamines in human milk are essential for the rapid growth and development of neonates and infants. However, the concentrations of polyamines in human milk have not been well characterized and the special methods for detecting polyamines in human milk, formula milk, or other dairy products remain largely unavailable to date. In this study, an accurate and sensitive method based on trifluoroacetic acid anhydride (TFAA) derivatization, double solid-phase extraction (SPE) purification, and gas chromatography-triple quadrupole mass spectrometry (GC-QqQ MS) was established for the evaluation of polyamines in human milk, formula milk, and other dairy products. High coefficients of determination for internal calibration curves were obtained (<i>R</i><sup>2</sup> > 0.99). Low limits of detection (5.0, 1.0, and 0.5 nmol/dL) and limits of quantification (10.0, 3.0, and 1.0 nmol/dL) for putrescine, spermidine, and spermine, respectively, were also achieved. The precision (expressed as relative standard deviation, RSD < 9.0%) and recovery rates (78.3-108.4%) were satisfactory. Spermidine and spermine in human milk were found significantly higher than those in formula milk and commercial cow's milk. The difference of polyamine content in human milk and infant formula should be paid attention to, particularly when infant formula is used as a complete replacement for human milk.

Journal of Agricultural and Food ChemistryVol. 73(14)
Nanjing Medical University (CN)
Priority Academic Program Development of Jiangsu Higher Education Institutions, National Key Research and Development Program of China
Zero hunger
Openalex Percentile: Top 30%
Polyamine Metabolism and Applications
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.