SENSITIVE ARSENITE DETECTION BASED ON GRAPHENE ION-SENSITIVE FIELD-EFFECT TRANSISTORS

Arsenite (As 3+ ) poses severe health risks, including cancers and cardiovascular diseases [1].Traditional colorimetric detection methods are portable yet inaccurate, contrasting with sensitive yet non-real-time ICP-MS.Ion-sensitive field-effect transistors (ISFETs) are emerging as sensitive, low-limit, real-time potentiometric sensors, yet complex and expensive biosensors still dominate [2].To address these challenges, we fabricate lowcost As 3+ sensors using interdigital graphene ISFETs integrated with 5,10,15,20-Tetrakis(4-methoxyphenyl)-21H,23H-porphine cobalt (II) (TMOPP-Co) ion-sensitive membranes (ISM), achieving a wide detection range (0.1 ppt to 10 ppm) and an ultralow limit of detection (0.1 ppt).Moreover, sensitivity in water and PBS buffer, is 18 mV/decade and 13 mV/decade, respectively.

Authors

Publication Details

Published
2024-10-07
DOI
https://doi.org/10.70477/slgk4223
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SENSITIVE ARSENITE DETECTION BASED ON GRAPHENE ION-SENSITIVE FIELD-EFFECT TRANSISTORS

Tianhong Cui, Terrence W. Simon, Peng Zhou, Yingming Xu
Analytical Chemistry and Sensors
article

SENSITIVE ARSENITE DETECTION BASED ON GRAPHENE ION-SENSITIVE FIELD-EFFECT TRANSISTORS

Tianhong Cui, Terrence W. Simon, Peng Zhou, Yingming Xu
article en

Abstract

Arsenite (As 3+ ) poses severe health risks, including cancers and cardiovascular diseases [1].Traditional colorimetric detection methods are portable yet inaccurate, contrasting with sensitive yet non-real-time ICP-MS.Ion-sensitive field-effect transistors (ISFETs) are emerging as sensitive, low-limit, real-time potentiometric sensors, yet complex and expensive biosensors still dominate [2].To address these challenges, we fabricate lowcost As 3+ sensors using interdigital graphene ISFETs integrated with 5,10,15,20-Tetrakis(4-methoxyphenyl)-21H,23H-porphine cobalt (II) (TMOPP-Co) ion-sensitive membranes (ISM), achieving a wide detection range (0.1 ppt to 10 ppm) and an ultralow limit of detection (0.1 ppt).Moreover, sensitivity in water and PBS buffer, is 18 mV/decade and 13 mV/decade, respectively.

Affordable and clean energy
Openalex Percentile: Top 71%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.