Detection of CO<sub>2</sub> Locally Generated by Formate Dehydrogenase Using Carbonate Ion-Selective Micropipette Electrodes

Many technologies involve immobilizing catalysts such as enzymes on surfaces, and the catalytic activities or functional efficiencies of these surface-bound catalysts can vary depending on orientations, localized binding sites, active sites, and intrinsic molecular nature. Accurate and rapid quantification of reaction products from surface-immobilized catalysts is crucial for understanding the selectivity, mechanisms, and reaction dynamics of catalytic systems and for revealing heterogeneous catalytic activities and reaction sites for applications such as biosensors and energy conversion/generation systems. Here, we demonstrate the feasibility of localized enzymatic activity measurements using microscale carbon dioxide (CO<sub>2</sub>)-sensitive ion-selective electrode (ISE) pipettes (0.5-2.5 μm tip radius) as a probe, with in situ potentiometric scanning electrochemical microscopy (SECM). We develop carbonate (CO<sub>3</sub><sup>2-</sup>) ionophore-incorporated ISEs exhibiting a Nernstian response (26.7 mV/decade) with a detection limit of 1.72 μM and explore surface-immobilized formate dehydrogenase (FDH) activity by detecting CO<sub>2</sub> generated by the enzymatic reaction via potentiometric measurements. SECM is used for real-time spatial/temporal investigation of FDH immobilized onto the surface at a micrometer-scale resolution. Moreover, unlike voltammetric techniques based on faradaic reactions, the potentiometric measurements using ISEs allow highly sensitive and selective detection of CO<sub>3</sub><sup>2-</sup>, rendering efficient quantification of CO<sub>2</sub> without interference from solution composition changes arising from faradaic processes. The total amount of CO<sub>2</sub> generated at an FDH-immobilized Au ultramicroelectrode is quantified as a function of coenzyme, i.e., NAD<sup>+</sup>, and substrate, i.e., formate, concentrations both in constant tip-sample distance mode and variable depth mode. Finally, we demonstrate the use of the ISE to quantify CO<sub>2</sub> levels in blood serum.

Authors

Institutions

Publication Details

Journal
ACS Nano
Published
2025-03-25
DOI
https://doi.org/10.1021/acsnano.5c00387
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of CO2 Locally Generated by Formate Dehydrogenase Using Carbonate Ion-Selective Micropipette Electrodes

Sean R. German, Salvador Gutierrez‐Portocarrero, Shelley D. Minteer, Rokas Gerulskis et al.
1 citations
ACS Nano
Electrochemical sensors and biosensors
0.73
article

Detection of CO2 Locally Generated by Formate Dehydrogenase Using Carbonate Ion-Selective Micropipette Electrodes

Sean R. German, Salvador Gutierrez‐Portocarrero, Shelley D. Minteer, Rokas Gerulskis, Henry S. White, Seol Baek
article en
1 citations

Abstract

Many technologies involve immobilizing catalysts such as enzymes on surfaces, and the catalytic activities or functional efficiencies of these surface-bound catalysts can vary depending on orientations, localized binding sites, active sites, and intrinsic molecular nature. Accurate and rapid quantification of reaction products from surface-immobilized catalysts is crucial for understanding the selectivity, mechanisms, and reaction dynamics of catalytic systems and for revealing heterogeneous catalytic activities and reaction sites for applications such as biosensors and energy conversion/generation systems. Here, we demonstrate the feasibility of localized enzymatic activity measurements using microscale carbon dioxide (CO<sub>2</sub>)-sensitive ion-selective electrode (ISE) pipettes (0.5-2.5 μm tip radius) as a probe, with in situ potentiometric scanning electrochemical microscopy (SECM). We develop carbonate (CO<sub>3</sub><sup>2-</sup>) ionophore-incorporated ISEs exhibiting a Nernstian response (26.7 mV/decade) with a detection limit of 1.72 μM and explore surface-immobilized formate dehydrogenase (FDH) activity by detecting CO<sub>2</sub> generated by the enzymatic reaction via potentiometric measurements. SECM is used for real-time spatial/temporal investigation of FDH immobilized onto the surface at a micrometer-scale resolution. Moreover, unlike voltammetric techniques based on faradaic reactions, the potentiometric measurements using ISEs allow highly sensitive and selective detection of CO<sub>3</sub><sup>2-</sup>, rendering efficient quantification of CO<sub>2</sub> without interference from solution composition changes arising from faradaic processes. The total amount of CO<sub>2</sub> generated at an FDH-immobilized Au ultramicroelectrode is quantified as a function of coenzyme, i.e., NAD<sup>+</sup>, and substrate, i.e., formate, concentrations both in constant tip-sample distance mode and variable depth mode. Finally, we demonstrate the use of the ISE to quantify CO<sub>2</sub> levels in blood serum.

ACS NanoVol. 19(13)
Missouri University of Science and Technology (US), University of Utah (US), Sookmyung Women's University (KR), Electronic BioSciences (United States) (US)
National Institute of General Medical Sciences
Openalex Percentile: Top 30%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.