Detection of CO<sub>2</sub> Locally Generated by Formate Dehydrogenase Using Carbonate Ion-Selective Micropipette Electrodes
Many technologies involve immobilizing catalysts such as enzymes on surfaces, and the catalytic activities or functional efficiencies of these surface-bound catalysts can vary depending on orientations, localized binding sites, active sites, and intrinsic molecular nature. Accurate and rapid quantification of reaction products from surface-immobilized catalysts is crucial for understanding the selectivity, mechanisms, and reaction dynamics of catalytic systems and for revealing heterogeneous catalytic activities and reaction sites for applications such as biosensors and energy conversion/generation systems. Here, we demonstrate the feasibility of localized enzymatic activity measurements using microscale carbon dioxide (CO<sub>2</sub>)-sensitive ion-selective electrode (ISE) pipettes (0.5-2.5 μm tip radius) as a probe, with in situ potentiometric scanning electrochemical microscopy (SECM). We develop carbonate (CO<sub>3</sub><sup>2-</sup>) ionophore-incorporated ISEs exhibiting a Nernstian response (26.7 mV/decade) with a detection limit of 1.72 μM and explore surface-immobilized formate dehydrogenase (FDH) activity by detecting CO<sub>2</sub> generated by the enzymatic reaction via potentiometric measurements. SECM is used for real-time spatial/temporal investigation of FDH immobilized onto the surface at a micrometer-scale resolution. Moreover, unlike voltammetric techniques based on faradaic reactions, the potentiometric measurements using ISEs allow highly sensitive and selective detection of CO<sub>3</sub><sup>2-</sup>, rendering efficient quantification of CO<sub>2</sub> without interference from solution composition changes arising from faradaic processes. The total amount of CO<sub>2</sub> generated at an FDH-immobilized Au ultramicroelectrode is quantified as a function of coenzyme, i.e., NAD<sup>+</sup>, and substrate, i.e., formate, concentrations both in constant tip-sample distance mode and variable depth mode. Finally, we demonstrate the use of the ISE to quantify CO<sub>2</sub> levels in blood serum.
Authors
- Sean R. German (ORCID: https://orcid.org/0000-0002-4636-4577)
- Salvador Gutierrez‐Portocarrero (ORCID: https://orcid.org/0000-0002-9154-2790)
- Shelley D. Minteer (ORCID: https://orcid.org/0000-0002-5788-2249)
- Rokas Gerulskis (ORCID: https://orcid.org/0000-0003-0370-679X)
- Henry S. White (ORCID: https://orcid.org/0000-0002-5053-0996)
- Seol Baek (ORCID: https://orcid.org/0000-0003-2191-6723)
Institutions
- Missouri University of Science and Technology (US)
- University of Utah (US)
- Sookmyung Women's University (KR)
- Electronic BioSciences (United States) (US)
Publication Details
- Journal
- ACS Nano
- Published
- 2025-03-25
- DOI
- https://doi.org/10.1021/acsnano.5c00387
- Citations
- 1
- Primary Topic
- Electrochemical sensors and biosensors
- Type
- article
- Field-Weighted Citation Impact
- 0.73
Funders
- National Institute of General Medical Sciences