Smartwatch-Derived VO2max Prediction Model for Korean Adults: Utilizing Heart Rate and GPS Data from the 12-Minute Cooper Test

<b>Background/Objectives</b>: Recent technological advancements enable smartwatches to measure running distance and heart rate using wearable sensors. This study aimed to analyze the validity of the 12 min Cooper test using a smartwatch and to develop an accurate VO2max prediction model for Korean adults. <b>Methods</b>: A total of 104 adults (53 males: age 35.00 ± 6.1 years, BMI 24.71 ± 3.13; 51 females: age 34.82 ± 6.07 years, BMI 22.24 ± 2.66) participated. VO2max was measured using a maximal graded treadmill test. Participants performed the Cooper test while wearing a smartwatch, which collected average heart rate, peak heart rate, and running distance. Sex, height, and weight were also included as predictor variables. Multiple regression analysis was conducted to develop a VO2max prediction equation. Model accuracy was assessed using R<sup>2</sup> and the standard error of the estimate (SEE). <b>Results</b>: The developed VO2max prediction equation was VO2max = 27.620 + 6.358 (sex; male = 1, female = 0) - 0.012 (height) - 0.202 (weight) - 0.036 (mean HR) + 0.039 (peak HR) + 0.012 (distance) (R<sup>2</sup> = 0.853, SEE = 3.176 mL/kg/min, <i>p</i> < 0.001). The intra-class correlation coefficient (ICC) between measured and predicted VO2max using the smartwatch was 0.961, compared to 0.925 for traditional methods. The explanatory power was 86.0% (SEE = 3.024 mL/kg/min) versus 81.0% (SEE = 3.516 mL/kg/min). <b>Conclusions</b>: The smartwatch-based VO2max prediction model demonstrated higher accuracy than traditional methods. This equation is recommended for more precise VO2max estimation in Korean adults.

Authors

Institutions

Publication Details

Journal
Healthcare
Published
2025-03-25
DOI
https://doi.org/10.3390/healthcare13070722
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smartwatch-Derived VO2max Prediction Model for Korean Adults: Utilizing Heart Rate and GPS Data from the 12-Minute Cooper Test

Kihyuk Lee, Aera Jang, Do‐Hee Kim, Jinwook Chung et al.
1 citations
Healthcare
Non-Invasive Vital Sign Monitoring
0.67
article

Smartwatch-Derived VO2max Prediction Model for Korean Adults: Utilizing Heart Rate and GPS Data from the 12-Minute Cooper Test

Kihyuk Lee, Aera Jang, Do‐Hee Kim, Jinwook Chung, Hongjun Choi, Sungeun Shin
article en
1 citations

Abstract

<b>Background/Objectives</b>: Recent technological advancements enable smartwatches to measure running distance and heart rate using wearable sensors. This study aimed to analyze the validity of the 12 min Cooper test using a smartwatch and to develop an accurate VO2max prediction model for Korean adults. <b>Methods</b>: A total of 104 adults (53 males: age 35.00 ± 6.1 years, BMI 24.71 ± 3.13; 51 females: age 34.82 ± 6.07 years, BMI 22.24 ± 2.66) participated. VO2max was measured using a maximal graded treadmill test. Participants performed the Cooper test while wearing a smartwatch, which collected average heart rate, peak heart rate, and running distance. Sex, height, and weight were also included as predictor variables. Multiple regression analysis was conducted to develop a VO2max prediction equation. Model accuracy was assessed using R<sup>2</sup> and the standard error of the estimate (SEE). <b>Results</b>: The developed VO2max prediction equation was VO2max = 27.620 + 6.358 (sex; male = 1, female = 0) - 0.012 (height) - 0.202 (weight) - 0.036 (mean HR) + 0.039 (peak HR) + 0.012 (distance) (R<sup>2</sup> = 0.853, SEE = 3.176 mL/kg/min, <i>p</i> < 0.001). The intra-class correlation coefficient (ICC) between measured and predicted VO2max using the smartwatch was 0.961, compared to 0.925 for traditional methods. The explanatory power was 86.0% (SEE = 3.024 mL/kg/min) versus 81.0% (SEE = 3.516 mL/kg/min). <b>Conclusions</b>: The smartwatch-based VO2max prediction model demonstrated higher accuracy than traditional methods. This equation is recommended for more precise VO2max estimation in Korean adults.

HealthcareVol. 13(7)
Dongguk University (KR), Seoul National University Bundang Hospital (KR)
Openalex Percentile: Top 34%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.