Respiratory Monitoring with Textile Inductive Electrodes in Driving Applications: Effect of Electrode’s Positioning and Form Factor on Signal Quality

This paper provides insights into where and how to integrate textile inductive electrodes into a car to record optimal-quality respiratory signals. Electrodes of various shapes and sizes were integrated into the seat belt and the seat back of a driving simulator car seat. The electrodes covered various parts of the body: upper back, middle back, lower back, chest, and waist. Three subjects completed driving circuits with their breathing signals being recorded. In general, signal quality while driving versus sitting still was similar, compared to a previous study of ours with no body movements. In terms of positioning, electrodes on seat belt provided better signal quality compared to seat back. Signal quality was directly proportional to electrode's height on the back, with upper back outperforming both middle and lower back. Electrodes on the waist provided either similar or superior signal quality compared to electrodes on the chest. In terms of form factor, rectangular shape outperformed circular shape on seat back. Signal quality is proportional to the size of circular electrodes on seat back, and inversely proportional to size of rectangular electrode on seat belt.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-03-25
DOI
https://doi.org/10.3390/s25072035
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Respiratory Monitoring with Textile Inductive Electrodes in Driving Applications: Effect of Electrode’s Positioning and Form Factor on Signal Quality

Ghyslain Gagnon, Patricia Forcier, Alireza Saïdi, Justine Decaens et al.
1 citations
Sensors
Non-Invasive Vital Sign Monitoring
0.67
article

Respiratory Monitoring with Textile Inductive Electrodes in Driving Applications: Effect of Electrode’s Positioning and Form Factor on Signal Quality

Ghyslain Gagnon, Patricia Forcier, Alireza Saïdi, Justine Decaens, James Elber Duverger, Victor Bellemin, Geordi-Gabriel Renaud Dumoulin
article en
1 citations

Abstract

This paper provides insights into where and how to integrate textile inductive electrodes into a car to record optimal-quality respiratory signals. Electrodes of various shapes and sizes were integrated into the seat belt and the seat back of a driving simulator car seat. The electrodes covered various parts of the body: upper back, middle back, lower back, chest, and waist. Three subjects completed driving circuits with their breathing signals being recorded. In general, signal quality while driving versus sitting still was similar, compared to a previous study of ours with no body movements. In terms of positioning, electrodes on seat belt provided better signal quality compared to seat back. Signal quality was directly proportional to electrode's height on the back, with upper back outperforming both middle and lower back. Electrodes on the waist provided either similar or superior signal quality compared to electrodes on the chest. In terms of form factor, rectangular shape outperformed circular shape on seat back. Signal quality is proportional to the size of circular electrodes on seat back, and inversely proportional to size of rectangular electrode on seat belt.

SensorsVol. 25(7)
Institut de recherche Robert-Sauvé en santé et en sécurité du travail (CA), Université du Québec à Montréal (CA), CTT Group (Canada) (CA), École de Technologie Supérieure (CA)
Institut de Recherche Robert-Sauvé en Santé et en Sécurité du Travail, Mitacs
Openalex Percentile: Top 34%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Respiratory Monitoring with Textile Inductive Electrodes in Driving Applications: Effect of Electrode’s Positioning and Form Factor on Signal Quality — Ghyslain Gagnon, Patricia Forcier, et al. · Sensors (2025) | TGRS Research Map | TGRS