Box–Behnken optimized MPA-CdTe quantum dots as turn-off fluorescent probes for sensitive lurasidone determination in pharmaceutical, biological, and environmental matrices

A sensitive and selective fluorescence quenching method was developed for the determination of lurasidone using MPA-CdTe quantum dots as a "turn-off" fluorescent probe. The fluorescence intensity of the MPA-CdTe QDs was quenched upon the addition of lurasidone, with the quenching efficiency exhibiting a linear relationship with the lurasidone concentration in the range of 0.02-1.0 μg mL<sup>-1</sup>. Stern-Volmer analysis revealed that the quenching mechanism was predominantly static in nature, and thermodynamic studies indicated that the interaction between lurasidone and MPA-CdTe QDs was exothermic and spontaneous in nature. Factors affecting the quenching process, including pH, MPA-CdTe QDs volume, and incubation time, were optimized using a Box-Behnken experimental design. A significant model was obtained with a coefficient of determination (<i>R</i> <sup>2</sup>) of 0.9547, demonstrating the reliability of the optimization process. The analytical performance of the method was validated according to ICH guidelines, exhibiting good linearity and sensitivity with LOD of 5.90 ng mL<sup>-1</sup> and LOQ of 17.70 ng mL<sup>-1</sup>. The accuracy and precision of the method were assessed through recovery studies, showing satisfactory results with a mean recovery of 98.65 ± 0.733% and RSD% > 2%. The proposed method was successfully applied to the analysis of lurasidone in pharmaceutical dosage forms, spiked plasma, and environmental water samples, with good recoveries and precision. The greenness and analytical practicality of the method were evaluated using AGREE and BAGI tools, respectively, and the results showed that the proposed method is a greener and more practical alternative to previously reported analytical techniques for the determination of lurasidone. The present study demonstrates the potential of MPA-CdTe QDs as a sensitive and selective fluorescent probe for the determination of lurasidone in various matrices, with good analytical performance and environmental compatibility.

Authors

Institutions

Publication Details

Journal
RSC Advances
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ra00519a
Citations
7
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
5.27

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Box–Behnken optimized MPA-CdTe quantum dots as turn-off fluorescent probes for sensitive lurasidone determination in pharmaceutical, biological, and environmental matrices

Razaz Abdulaziz Felemban, Mohammed F. Aldawsari, Maram H. Abduljabbar, Rami M. Alzhrani et al.
7 citations
RSC Advances
Analytical chemistry methods development
5.27
article

Box–Behnken optimized MPA-CdTe quantum dots as turn-off fluorescent probes for sensitive lurasidone determination in pharmaceutical, biological, and environmental matrices

Razaz Abdulaziz Felemban, Mohammed F. Aldawsari, Maram H. Abduljabbar, Rami M. Alzhrani, Ahmed Serag, Atiah H. Almalki, Reem M. Alnemari, Yusuf S. Althobaiti
article en
7 citations

Abstract

A sensitive and selective fluorescence quenching method was developed for the determination of lurasidone using MPA-CdTe quantum dots as a "turn-off" fluorescent probe. The fluorescence intensity of the MPA-CdTe QDs was quenched upon the addition of lurasidone, with the quenching efficiency exhibiting a linear relationship with the lurasidone concentration in the range of 0.02-1.0 μg mL<sup>-1</sup>. Stern-Volmer analysis revealed that the quenching mechanism was predominantly static in nature, and thermodynamic studies indicated that the interaction between lurasidone and MPA-CdTe QDs was exothermic and spontaneous in nature. Factors affecting the quenching process, including pH, MPA-CdTe QDs volume, and incubation time, were optimized using a Box-Behnken experimental design. A significant model was obtained with a coefficient of determination (<i>R</i> <sup>2</sup>) of 0.9547, demonstrating the reliability of the optimization process. The analytical performance of the method was validated according to ICH guidelines, exhibiting good linearity and sensitivity with LOD of 5.90 ng mL<sup>-1</sup> and LOQ of 17.70 ng mL<sup>-1</sup>. The accuracy and precision of the method were assessed through recovery studies, showing satisfactory results with a mean recovery of 98.65 ± 0.733% and RSD% > 2%. The proposed method was successfully applied to the analysis of lurasidone in pharmaceutical dosage forms, spiked plasma, and environmental water samples, with good recoveries and precision. The greenness and analytical practicality of the method were evaluated using AGREE and BAGI tools, respectively, and the results showed that the proposed method is a greener and more practical alternative to previously reported analytical techniques for the determination of lurasidone. The present study demonstrates the potential of MPA-CdTe QDs as a sensitive and selective fluorescent probe for the determination of lurasidone in various matrices, with good analytical performance and environmental compatibility.

RSC AdvancesVol. 15(12)
Prince Sattam Bin Abdulaziz University (SA), Taif University (SA), Al-Azhar University (EG), King Saud bin Abdulaziz University for Health Sciences (SA), King Abdullah International Medical Research Center (SA)
Taif University
Clean water and sanitation
Openalex Percentile: Top 4%
Analytical chemistry methods development
5.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.