New Concept of Colonoscopy Assisted by a Microwave-Based Accessory Device: First Clinical Experience

<b>Background/Objectives</b>: Colonoscopies have some limitations that result in a miss rate detection of polyps. Microwave imaging has been demonstrated to detect colorectal polyps based on their dielectric properties in synthetic phantoms, ex vivo tissues and in vivo animal models. This study aims to evaluate, for the first time, the feasibility, safety and performance of microwave-based colonoscopy for diagnosis of polyps in real-time explorations in humans. <b>Methods</b>: This was a single-center, prospective, observational study. Patients referred for diagnostic colonoscopy were explored with a device with microwave antennas which was attached to the tip of a standard colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for the detection of polyps. Secondary outcomes were the following: patients' subjective feedback, procedural time and perception of difficulty according to the endoscopist. <b>Results</b>: Fifteen patients were enrolled. Cecal intubation rate was 100%, with a mean time of 12.7 ± 4.9 min (range 4-22). Use of the device did not affect the endoscopic image, and polypectomy was successfully performed in all cases. In on scale from zero (not difficult) to four (very difficult), the maneuverability during the insertion was considered ≤2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) reported no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. <b>Conclusions</b>: microwave-based colonoscopy is safe and feasible and has the potential to detect polyps in real colonoscopies.

Authors

Institutions

Publication Details

Journal
Cancers
Published
2025-03-22
DOI
https://doi.org/10.3390/cancers17071073
Citations
1
Primary Topic
Colorectal Cancer Screening and Detection
Type
article
Field-Weighted Citation Impact
1.05

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

New Concept of Colonoscopy Assisted by a Microwave-Based Accessory Device: First Clinical Experience

Glòria Fernández‐Esparrach, Marta Guardiola, Alejandra Garrido, Oswaldo Ortíz et al.
1 citations
Cancers
Colorectal Cancer Screening and Detection
1.05
article

New Concept of Colonoscopy Assisted by a Microwave-Based Accessory Device: First Clinical Experience

Glòria Fernández‐Esparrach, Marta Guardiola, Alejandra Garrido, Oswaldo Ortíz, Luz María Neira, Oriol Sendino, Silvia Rivadulla, Josep Martí Sanahuja-Blasco, Pilar Sesé
article en
1 citations

Abstract

<b>Background/Objectives</b>: Colonoscopies have some limitations that result in a miss rate detection of polyps. Microwave imaging has been demonstrated to detect colorectal polyps based on their dielectric properties in synthetic phantoms, ex vivo tissues and in vivo animal models. This study aims to evaluate, for the first time, the feasibility, safety and performance of microwave-based colonoscopy for diagnosis of polyps in real-time explorations in humans. <b>Methods</b>: This was a single-center, prospective, observational study. Patients referred for diagnostic colonoscopy were explored with a device with microwave antennas which was attached to the tip of a standard colonoscope. The primary outcomes were rate of cecal intubation, adverse events, mural injuries and performance metrics for the detection of polyps. Secondary outcomes were the following: patients' subjective feedback, procedural time and perception of difficulty according to the endoscopist. <b>Results</b>: Fifteen patients were enrolled. Cecal intubation rate was 100%, with a mean time of 12.7 ± 4.9 min (range 4-22). Use of the device did not affect the endoscopic image, and polypectomy was successfully performed in all cases. In on scale from zero (not difficult) to four (very difficult), the maneuverability during the insertion was considered ≤2 in the 86.7% (13/15) of colonoscopies. Only 16 incidents were reported in 14 patients: 11 (67%) superficial hematomas, 2 minor rectal bleedings, 1 anal fissure, 1 rhinorrhea and 1 headache. Most of the patients (94%) reported no discomfort or minimal discomfort before discharge (Gloucester score 1 and 2, respectively). In the six patients with 23 polyps used for the performance analysis, the sensitivity and specificity were 86.9% and 72.0%, respectively. <b>Conclusions</b>: microwave-based colonoscopy is safe and feasible and has the potential to detect polyps in real colonoscopies.

CancersVol. 17(7)
Departament de Salut (ES), Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (ES), Consorci Institut D'Investigacions Biomediques August Pi I Sunyer (ES), Universitat de Barcelona (ES)
European Commission, Instituto de Salud Carlos III
Openalex Percentile: Top 24%
Colorectal Cancer Screening and Detection
1.05
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.