Secondary-Fault Diagnosis of a Rotating Rectifier in a Three-Stage Starter-Generator Based on the Idle Winding Terminal Voltage

Based on the stator idle winding terminal voltage of the main exciter when the system works in generation state, a diagnosis method for secondary faults in the rotating rectifier when a single diode has failed in an open-circuit is proposed. In this method, secondary-fault diagnosis of rotating rectifier is achieved by combining the characteristic voltage ratio R and the number (denoted as Q) of values among voltage ratio R<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">I</inf>, RIIand RI11 that fall within the threshold range. The experimental results validate the feasibility and effectiveness of this method.

Authors

Institutions

Publication Details

Published
2024-11-26
DOI
https://doi.org/10.23919/icems60997.2024.10921291
Primary Topic
Engineering Diagnostics and Reliability
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Secondary-Fault Diagnosis of a Rotating Rectifier in a Three-Stage Starter-Generator Based on the Idle Winding Terminal Voltage

Ji Pang, Chenghao Sun, Shuye Ding, Shoucheng Li et al.
Engineering Diagnostics and Reliability
article

Secondary-Fault Diagnosis of a Rotating Rectifier in a Three-Stage Starter-Generator Based on the Idle Winding Terminal Voltage

Ji Pang, Chenghao Sun, Shuye Ding, Shoucheng Li, Xinyu Li, Jiawei Zhang, Shaochi Cheng, Wenjing Xu
article en

Abstract

Based on the stator idle winding terminal voltage of the main exciter when the system works in generation state, a diagnosis method for secondary faults in the rotating rectifier when a single diode has failed in an open-circuit is proposed. In this method, secondary-fault diagnosis of rotating rectifier is achieved by combining the characteristic voltage ratio R and the number (denoted as Q) of values among voltage ratio R<inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">I</inf>, RIIand RI11 that fall within the threshold range. The experimental results validate the feasibility and effectiveness of this method.

Nanjing Normal University (CN), State Grid Corporation of China (China) (CN), Xi’an University of Posts and Telecommunications (CN)
Natural Science Foundation of Jiangsu Province, Natural Science Foundation of Shaanxi Province, Natural Science Foundation of Shaanxi Provincial Department of Education
Affordable and clean energy
Openalex Percentile: Top 69%
Engineering Diagnostics and Reliability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.