A Current-Limiting Scheme with Adjustable Virtual Impedance for Three-Phase Four-Wire Grid Forming Inverters

This paper presents a current-limiting scheme for the three-phase four-wire grid-forming inverters. The concept of virtual synchronous generator is employed. The proposed current limitation scheme is applied to each phase independently without interrupting the unfaulty phases. In addition, the current limit in the neutral is taken into consideration. Both virtual inductance and virtual resistance are automatically adjusted based on the amount of overcurrent. To mimic the behavior of a synchronous generator during the occurrence of faults, the cooperation between virtual resistance and inductance is proposed; the virtual resistance provides the fast response against the transient fault current while the virtual inductance is dedicated to limit the steady-state fault current. Simulation results show that the current in each phase is effectively limited for various types of faults in both grid-connected and islanded operations.

Authors

Institutions

Publication Details

Published
2024-11-26
DOI
https://doi.org/10.23919/icems60997.2024.10920971
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Current-Limiting Scheme with Adjustable Virtual Impedance for Three-Phase Four-Wire Grid Forming Inverters

Somboon Sangwongwanich, Preenapan Panya, Surapong Suwankawin
1 links
HVDC Systems and Fault Protection
article

A Current-Limiting Scheme with Adjustable Virtual Impedance for Three-Phase Four-Wire Grid Forming Inverters

Somboon Sangwongwanich, Preenapan Panya, Surapong Suwankawin
article en

Abstract

This paper presents a current-limiting scheme for the three-phase four-wire grid-forming inverters. The concept of virtual synchronous generator is employed. The proposed current limitation scheme is applied to each phase independently without interrupting the unfaulty phases. In addition, the current limit in the neutral is taken into consideration. Both virtual inductance and virtual resistance are automatically adjusted based on the amount of overcurrent. To mimic the behavior of a synchronous generator during the occurrence of faults, the cooperation between virtual resistance and inductance is proposed; the virtual resistance provides the fast response against the transient fault current while the virtual inductance is dedicated to limit the steady-state fault current. Simulation results show that the current in each phase is effectively limited for various types of faults in both grid-connected and islanded operations.

Chulalongkorn University (TH)
Affordable and clean energy
Openalex Percentile: Top 73%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Current-Limiting Scheme with Adjustable Virtual Impedance for Three-Phase Four-Wire Grid Forming Inverters — Somboon Sangwongwanich, Preenapan Panya, et al. · (2024) | TGRS Research Map | TGRS