Pulsation Reducing Effect in DC Current and Torque for Motor Fault-Tolerance Based on Second Order Component Power Cancelation

This paper proposed a novel fault-tolerance control method. In the conventional method, reverse-phase component in phase current was canceled to reduce torque ripple while maintaining average torque. On the other hand, since zero-phase current was utilized, motor driving with H-bridge inverters was mandatory. Moreover, the feedback system had not been constructed, resulting in enormous effort for achieving accurate control. In this research, to realize reverse-phase cancelation with half-bridge inverters, the fault-tolerant control method that cancels the 2nd-order component of electric power under the non-zero-phase current constraint was developed. Moreover, the feedback system for the reverse-phase current superimposition was constructed. In this paper, the numerical verification using MATLAB/Simulink was conducted to validate the effectiveness of the proposed method. Moreover, the obtained results were compared with conventional methods.

Authors

Institutions

Publication Details

Published
2024-11-26
DOI
https://doi.org/10.23919/icems60997.2024.10921065
Primary Topic
Machine Fault Diagnosis Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulsation Reducing Effect in DC Current and Torque for Motor Fault-Tolerance Based on Second Order Component Power Cancelation

Sota Takahashi, Yuki Hidaka
Machine Fault Diagnosis Techniques
article

Pulsation Reducing Effect in DC Current and Torque for Motor Fault-Tolerance Based on Second Order Component Power Cancelation

Sota Takahashi, Yuki Hidaka
article en

Abstract

This paper proposed a novel fault-tolerance control method. In the conventional method, reverse-phase component in phase current was canceled to reduce torque ripple while maintaining average torque. On the other hand, since zero-phase current was utilized, motor driving with H-bridge inverters was mandatory. Moreover, the feedback system had not been constructed, resulting in enormous effort for achieving accurate control. In this research, to realize reverse-phase cancelation with half-bridge inverters, the fault-tolerant control method that cancels the 2nd-order component of electric power under the non-zero-phase current constraint was developed. Moreover, the feedback system for the reverse-phase current superimposition was constructed. In this paper, the numerical verification using MATLAB/Simulink was conducted to validate the effectiveness of the proposed method. Moreover, the obtained results were compared with conventional methods.

Nagaoka University of Technology (JP)
Affordable and clean energy
Openalex Percentile: Top 64%
Machine Fault Diagnosis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pulsation Reducing Effect in DC Current and Torque for Motor Fault-Tolerance Based on Second Order Component Power Cancelation — Sota Takahashi, Yuki Hidaka · (2024) | TGRS Research Map | TGRS