Development and Validation of a Partial Discharge Simulation Platform for Transformer Insulation Monitoring

The stable operation of transformers is critical for power grid security. And the partial discharges detection is important to avoid insulation risk. Accurate detection of partial discharge signals remains challenging due to their weak, nonlinear, and random nature. This study developed a partial discharge simulation platform to replicate signals under various conditions. The platform design considers real transformer winding electric fields, installation constraints, and performance reliability. It features reusable discharge models simulating oil gap and suspension discharges. A UHF sensing detection system, covering 300 MHz to 1500 MHz with a 40 dB gain, was employed to validate the models. Experiment results showed that the detectable discharges of approximately 50 pC for oil gap and 30 pC for suspension models, demonstrating the platform is efficient.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/appeec61255.2024.10922105
Citations
1
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a Partial Discharge Simulation Platform for Transformer Insulation Monitoring

Wenzhi Chang, Tingyu Gao, Jiangang Bi, Shuai Yuan et al.
1 citations
High voltage insulation and dielectric phenomena
0.12
article

Development and Validation of a Partial Discharge Simulation Platform for Transformer Insulation Monitoring

Wenzhi Chang, Tingyu Gao, Jiangang Bi, Shuai Yuan, Chenlei Han
article en
1 citations

Abstract

The stable operation of transformers is critical for power grid security. And the partial discharges detection is important to avoid insulation risk. Accurate detection of partial discharge signals remains challenging due to their weak, nonlinear, and random nature. This study developed a partial discharge simulation platform to replicate signals under various conditions. The platform design considers real transformer winding electric fields, installation constraints, and performance reliability. It features reusable discharge models simulating oil gap and suspension discharges. A UHF sensing detection system, covering 300 MHz to 1500 MHz with a 40 dB gain, was employed to validate the models. Experiment results showed that the detectable discharges of approximately 50 pC for oil gap and 30 pC for suspension models, demonstrating the platform is efficient.

North China Electric Power University (CN), China Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 56%
High voltage insulation and dielectric phenomena
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.