Harmonic Response Analysis of 220 kV Oil-Immersed Transformer Winding And Core Under Preload

Power transformers are important equipment in the power system, but various faults are inevitable in the actual operation. If the transformer winding is deformed, it will lead to a decrease in the insulation and mechanical properties of the transformer, which in turn can cause transformer failure. In this article, a 220 kV three-phase oil immersed power transformer is taken as the research object. The vibration models of the transformer winding and core under different preloading forces are established using ANSYS Workbench. The structural modal analysis is carried out to obtain the natural frequencies and modal shapes of orders 1 to 6. Then, the mode superposition method is used for harmonic response analysis to obtain the analysis results. The results show that under the influence of preloading force, the modal vibration mode of the transformer structure remains basically unchanged, but the corresponding modal frequencies of each order change with the preloading force. Based on the results of modal analysis and harmonic response analysis, the reasonable setting of preload force for transformer windings can be guided, which can be used to identify weak links in the operation of transformers, and to reduce the impact of short circuit electromagnetic force and magnetostrictive vibration on transformers by setting reasonable factory preload force.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/appeec61255.2024.10922619
Primary Topic
Power Transformer Diagnostics and Insulation
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic Response Analysis of 220 kV Oil-Immersed Transformer Winding And Core Under Preload

Ruijuan Tan, Chunyan Zang, Haiyan Long, Peng Li et al.
Power Transformer Diagnostics and Insulation
article

Harmonic Response Analysis of 220 kV Oil-Immersed Transformer Winding And Core Under Preload

Ruijuan Tan, Chunyan Zang, Haiyan Long, Peng Li, Hongjie Xu, Dandan Zhang
article en

Abstract

Power transformers are important equipment in the power system, but various faults are inevitable in the actual operation. If the transformer winding is deformed, it will lead to a decrease in the insulation and mechanical properties of the transformer, which in turn can cause transformer failure. In this article, a 220 kV three-phase oil immersed power transformer is taken as the research object. The vibration models of the transformer winding and core under different preloading forces are established using ANSYS Workbench. The structural modal analysis is carried out to obtain the natural frequencies and modal shapes of orders 1 to 6. Then, the mode superposition method is used for harmonic response analysis to obtain the analysis results. The results show that under the influence of preloading force, the modal vibration mode of the transformer structure remains basically unchanged, but the corresponding modal frequencies of each order change with the preloading force. Based on the results of modal analysis and harmonic response analysis, the reasonable setting of preload force for transformer windings can be guided, which can be used to identify weak links in the operation of transformers, and to reduce the impact of short circuit electromagnetic force and magnetostrictive vibration on transformers by setting reasonable factory preload force.

North China Electric Power University (CN), China Electric Power Research Institute, Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 73%
Power Transformer Diagnostics and Insulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Harmonic Response Analysis of 220 kV Oil-Immersed Transformer Winding And Core Under Preload — Ruijuan Tan, Chunyan Zang, et al. · (2024) | TGRS Research Map | TGRS