Modeling and Stability Analysis for Weinberg Converter Using Peak Current Control Mode

Non-isolated Weinberg converter is competitive for battery discharge regulator(BDR) as a result of the merits of high efficiency, continuous input and output current and convenience to design. The aim of this work is to get a dynamic model of Weinberg converter with peak current control mode. It presents the conditions that the slope must satisfy in slope compensation, proposes the relationship between perturbation ratio and cut-off frequency and phase margin of current inner loop, and analyzes the impact of different perturbation ratio on the loop frequency response. The simulation results are given to verify the effectiveness of the design and modeling. Finally, an engineering prototype with a switching frequency same as the simulation was built, combined with high power pulse load to test. The results prove that dynamic performance of the converter is excellent when the load is working from the initial state to the steady state.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/appeec61255.2024.10922692
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modeling and Stability Analysis for Weinberg Converter Using Peak Current Control Mode

Weiyuan Ma, Jiao Su, Qiang Liu, Haitao Ding
HVDC Systems and Fault Protection
article

Modeling and Stability Analysis for Weinberg Converter Using Peak Current Control Mode

Weiyuan Ma, Jiao Su, Qiang Liu, Haitao Ding
article en

Abstract

Non-isolated Weinberg converter is competitive for battery discharge regulator(BDR) as a result of the merits of high efficiency, continuous input and output current and convenience to design. The aim of this work is to get a dynamic model of Weinberg converter with peak current control mode. It presents the conditions that the slope must satisfy in slope compensation, proposes the relationship between perturbation ratio and cut-off frequency and phase margin of current inner loop, and analyzes the impact of different perturbation ratio on the loop frequency response. The simulation results are given to verify the effectiveness of the design and modeling. Finally, an engineering prototype with a switching frequency same as the simulation was built, combined with high power pulse load to test. The results prove that dynamic performance of the converter is excellent when the load is working from the initial state to the steady state.

Beijing Satellite Navigation Center (CN)
Affordable and clean energy
Openalex Percentile: Top 73%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.