Equivalent Ratio of Frequency Regulation Resources Based on Derivation of Open-Loop Control Frequency Deviation

The conventional approach to frequency regulation predominantly relies on thermal and hydroelectric power generation units. As a growing variety of frequency regulation resources become accessible to power systems, there is significant variation in their performance characteristics, it is important to quantify their capabilities in the frequency service markets. This study introduces a technique to calculate the equivalent ratio of these resources by analyzing their primary response to frequency deviations derived from open-loop control. Based on the rotor motion equation of the generator, this paper constructs a load frequency control model incorporating two distinct regulation resources, linearize their outputs, and integrate them into the model. Through differential equations, this paper derives analytical expressions for the frequency deviation curve, enabling the determination of key frequency metrics. The equivalent ratio is then calculated by comparing the output power of resources with similar performance indicators. Finally, the paper investigates the impact of diverse parameters on the computation of the equivalent ratio employing simulation-based experimental analysis.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/appeec61255.2024.10922239
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Equivalent Ratio of Frequency Regulation Resources Based on Derivation of Open-Loop Control Frequency Deviation

Hanxiang Wang, Ying Wang, Jia Ning
Advanced Sensor and Control Systems
article

Equivalent Ratio of Frequency Regulation Resources Based on Derivation of Open-Loop Control Frequency Deviation

Hanxiang Wang, Ying Wang, Jia Ning
article en

Abstract

The conventional approach to frequency regulation predominantly relies on thermal and hydroelectric power generation units. As a growing variety of frequency regulation resources become accessible to power systems, there is significant variation in their performance characteristics, it is important to quantify their capabilities in the frequency service markets. This study introduces a technique to calculate the equivalent ratio of these resources by analyzing their primary response to frequency deviations derived from open-loop control. Based on the rotor motion equation of the generator, this paper constructs a load frequency control model incorporating two distinct regulation resources, linearize their outputs, and integrate them into the model. Through differential equations, this paper derives analytical expressions for the frequency deviation curve, enabling the determination of key frequency metrics. The equivalent ratio is then calculated by comparing the output power of resources with similar performance indicators. Finally, the paper investigates the impact of diverse parameters on the computation of the equivalent ratio employing simulation-based experimental analysis.

Nanjing Institute of Technology (CN), Southeast University (CN)
Openalex Percentile: Top 64%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.