A Robust Control Method for Active Dampers Against Filter Parameter Disturbance

Active dampers are effective in suppressing the resonance of grid-connected inverters by forming a virtual resistor with precisely designed control method in high frequency band. However, the inductance parameters of the filter can shift with the variation of power or temperature, which alters the precisely controlled virtual resistor to inductive or capacitive. To deal with the reduction of resonance suppression caused by the variation of the virtual resistor, an <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$H_{\infty}$</tex> robust control method is proposed against inductance parameter disturbance. The proposed scheme's effectiveness is validated through the execution of experimental results.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/appeec61255.2024.10922527
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Robust Control Method for Active Dampers Against Filter Parameter Disturbance

Ming He, Chen Peng, Fang Liu, Guoqin Gao et al.
Vibration Control and Rheological Fluids
article

A Robust Control Method for Active Dampers Against Filter Parameter Disturbance

Ming He, Chen Peng, Fang Liu, Guoqin Gao, Ye Tian
article en

Abstract

Active dampers are effective in suppressing the resonance of grid-connected inverters by forming a virtual resistor with precisely designed control method in high frequency band. However, the inductance parameters of the filter can shift with the variation of power or temperature, which alters the precisely controlled virtual resistor to inductive or capacitive. To deal with the reduction of resonance suppression caused by the variation of the virtual resistor, an <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$H_{\infty}$</tex> robust control method is proposed against inductance parameter disturbance. The proposed scheme's effectiveness is validated through the execution of experimental results.

Shanghai Electric (China) (CN)
Climate action
Openalex Percentile: Top 68%
Vibration Control and Rheological Fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.