Fault-Tolerant Control Method to Reduce Torque Ripple for Symmetrical Winding Multi-Phase Brushless DC Motor Under Open-Circuit Faults
For a symmetrical winding multi-phase brushless DC motor (BLDCM), this paper proposes a fault-tolerant control method to reduce torque ripple after an open-circuit fault occurs in the system. When a power switch device or phase winding experiences an open-circuit fault, the proposed method adjusts the conduction pattern of the windings in certain sectors, altering the magnitude and direction of the magnetomotive force (MMF) and thereby reducing torque ripple. This method is simple and easy to implement. It neither requires phase shifting of the healthy phases nor necessitates changes to all healthy phases. Finally, the effectiveness of the proposed method is verified through experiments on a 2kW nine-phase BLDCM experimental platform.
Authors
- Zhiqiang Wang (ORCID: https://orcid.org/0000-0002-0719-2047)
- Xinmin Li (ORCID: https://orcid.org/0000-0002-5089-3463)
- Wei Chen (ORCID: https://orcid.org/0000-0002-7381-2945)
- Lixiang Zhu (ORCID: https://orcid.org/0009-0002-1289-8877)
Institutions
- Tiangong University (CN)
Publication Details
- Published
- 2024-11-26
- DOI
- https://doi.org/10.23919/icems60997.2024.10921234
- Citations
- 1
- Primary Topic
- Power Systems and Renewable Energy
- Type
- article
- Field-Weighted Citation Impact
- 0.17
Funders
- National Natural Science Foundation of China