The Impact of Renewable Energy Fault Recovery Rate on the Transient Stability of the Sending-End Power Grid

The low voltage ride-through (LVRT) characteristics of renewable energy are different from the synchronous generators, resulting in the dynamic characteristics of power system are more complex after the integration of large-scale renewable energy. Therefore, the low voltage ride-through behavior, especially the fault recovery rate of renewable power needs to be considered. First, the mathematical model of the renewable energy during LVRT is presented, then the impacts of fault recovery rate on the transient stability of the analyzed based on a simple long-chain sending-end power system, with a conclusion that a lower fault recovery rate is more beneficial to the transient stability of the power system. Finally, a simulation example is built based on the PSASP platform, and the correctness of the proposed method is validated.

Authors

Institutions

Publication Details

Published
2024-10-25
DOI
https://doi.org/10.1109/appeec61255.2024.10922514
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Impact of Renewable Energy Fault Recovery Rate on the Transient Stability of the Sending-End Power Grid

Xiaorong Sun, Xueping Pan, Wenting Huang, Peng Zhou et al.
Power Systems Fault Detection
article

The Impact of Renewable Energy Fault Recovery Rate on the Transient Stability of the Sending-End Power Grid

Xiaorong Sun, Xueping Pan, Wenting Huang, Peng Zhou, Tao Xu, Jinpeng Guo
article en

Abstract

The low voltage ride-through (LVRT) characteristics of renewable energy are different from the synchronous generators, resulting in the dynamic characteristics of power system are more complex after the integration of large-scale renewable energy. Therefore, the low voltage ride-through behavior, especially the fault recovery rate of renewable power needs to be considered. First, the mathematical model of the renewable energy during LVRT is presented, then the impacts of fault recovery rate on the transient stability of the analyzed based on a simple long-chain sending-end power system, with a conclusion that a lower fault recovery rate is more beneficial to the transient stability of the power system. Finally, a simulation example is built based on the PSASP platform, and the correctness of the proposed method is validated.

Hohai University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 64%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.