Wearable Temperature Detection System for Personalised Health Tracking

The health of a human being is indicated by various vitals like heart rate, blood pressure, respiration rate, and body temperature, to name a few. An accurate measure of temperature is an essential parameter while monitoring temperature in critical conditions, especially for frontline workers, where continuous temperature measurement is of prime importance. This work analyses temperature sensors and explores various testing methods for response time and methods to improve the parameters. A customised PCB and temperature sensors were designed, fabricated, and tested. A custom-made Android app was also developed and tested to visualise the data from the sensors. The test results showed that the system developed has a quick response time of 4 to 6 seconds for a temperature change of 65°C and complies with military standards set by DRDO.

Authors

Institutions

Publication Details

Published
2025-02-07
DOI
https://doi.org/10.1109/icccit62592.2025.10928049
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable Temperature Detection System for Personalised Health Tracking

Srirangarajan Thorapalli Muralidharan, V. Bharadwaj, Deepali Koppad, M Divakara et al.
Advanced Chemical Sensor Technologies
article

Wearable Temperature Detection System for Personalised Health Tracking

Srirangarajan Thorapalli Muralidharan, V. Bharadwaj, Deepali Koppad, M Divakara, Tapan K. Nayak, S. Srikesh Iyer, Shakthi Varun KS
article en

Abstract

The health of a human being is indicated by various vitals like heart rate, blood pressure, respiration rate, and body temperature, to name a few. An accurate measure of temperature is an essential parameter while monitoring temperature in critical conditions, especially for frontline workers, where continuous temperature measurement is of prime importance. This work analyses temperature sensors and explores various testing methods for response time and methods to improve the parameters. A customised PCB and temperature sensors were designed, fabricated, and tested. A custom-made Android app was also developed and tested to visualise the data from the sensors. The test results showed that the system developed has a quick response time of 4 to 6 seconds for a temperature change of 65°C and complies with military standards set by DRDO.

Ballari Medical College and Research Centre (IN), M S Ramaiah University of Applied Sciences (IN)
Openalex Percentile: Top 95%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Wearable Temperature Detection System for Personalised Health Tracking — Srirangarajan Thorapalli Muralidharan, V. Bharadwaj, et al. · (2025) | TGRS Research Map | TGRS