H-Shaped Multi-Analyte PCF-Integrated SPR Sensor For Multi-Industry Fluid Analysis

This research conducts a numerical investigation of a multi-analyte H-patterned photonic crystal fiber (PCF) sensor utilizing surface plasmon resonance (SPR) technology developed to recognize industrial fluids in various medical and chemical applications efficiently. The sensor incorporates two fluid channels, simultaneously detecting multiple analytes. It uses a gold-titanium dioxidecoated plasmonic layer, providing high sensitivity, improved electric field confinement, and chemical stability. The sensor is optimized for refractive index ranges of 1.34-1.38 in channel-I and 1.39-1.43 in channel-II, both with high accuracy. This study aims to develop a platform for real-time analyte monitoring. The Finite Element Method is applied for arithmetical assessment after refining the sensor's architectural parameters. The sensor demonstrates a peak wavelength sensitivityof 4,000 nm/RIU in channel-I and 28,000 nm/RIU in channel-II. Additionally, it achieves maximum amplitude sensitivitiesof <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{410.64 }\text{RIU}^{-1}$</tex> and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$1561.55 \text{RIU}^{-1}$</tex> in the respective channels. This corresponds to a resolution of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$2.5 \times 10^{-{6}}$</tex> RIU for channel-I and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$3.57\times 10^{-7}$</tex> RIU for channel-II. This sensor is designed to detect unknown substances with RIs between 1.34 and 1.43, making it valuable for biological fluid diagnosis, food quality control, environmental monitoring, and chemical analysis.

Authors

Institutions

Publication Details

Published
2025-02-07
DOI
https://doi.org/10.1109/icccit62592.2025.10927760
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

H-Shaped Multi-Analyte PCF-Integrated SPR Sensor For Multi-Industry Fluid Analysis

Tanvir Ahmed, Most. Fahmida Sultana Mim
Microfluidic and Capillary Electrophoresis Applications
article

H-Shaped Multi-Analyte PCF-Integrated SPR Sensor For Multi-Industry Fluid Analysis

Tanvir Ahmed, Most. Fahmida Sultana Mim
article en

Abstract

This research conducts a numerical investigation of a multi-analyte H-patterned photonic crystal fiber (PCF) sensor utilizing surface plasmon resonance (SPR) technology developed to recognize industrial fluids in various medical and chemical applications efficiently. The sensor incorporates two fluid channels, simultaneously detecting multiple analytes. It uses a gold-titanium dioxidecoated plasmonic layer, providing high sensitivity, improved electric field confinement, and chemical stability. The sensor is optimized for refractive index ranges of 1.34-1.38 in channel-I and 1.39-1.43 in channel-II, both with high accuracy. This study aims to develop a platform for real-time analyte monitoring. The Finite Element Method is applied for arithmetical assessment after refining the sensor's architectural parameters. The sensor demonstrates a peak wavelength sensitivityof 4,000 nm/RIU in channel-I and 28,000 nm/RIU in channel-II. Additionally, it achieves maximum amplitude sensitivitiesof <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\text{410.64 }\text{RIU}^{-1}$</tex> and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$1561.55 \text{RIU}^{-1}$</tex> in the respective channels. This corresponds to a resolution of <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$2.5 \times 10^{-{6}}$</tex> RIU for channel-I and <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$3.57\times 10^{-7}$</tex> RIU for channel-II. This sensor is designed to detect unknown substances with RIs between 1.34 and 1.43, making it valuable for biological fluid diagnosis, food quality control, environmental monitoring, and chemical analysis.

Rajshahi University of Engineering and Technology (BD)
Industry, innovation and infrastructure
Openalex Percentile: Top 95%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

H-Shaped Multi-Analyte PCF-Integrated SPR Sensor For Multi-Industry Fluid Analysis — Tanvir Ahmed, Most. Fahmida Sultana Mim · (2025) | TGRS Research Map | TGRS